Skip to main content
Schneider Electric C60H3P32AB — 2-Pole MCB (DIN Rail)

Schneider C60H3P32AB MCB, 32A 3P B-Curve, 10kA

MPNC60H3P32AB
Obsolete

Schneider Electric, Multi9 series, C60H miniature circuit breaker, C60H3P32AB, 32 A, 3-pole, B-curve, 10 kA breaking capacity at 440 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C60H3P32AB — Identification
ParameterValue
Product nameC60
Product rangeC60
Series / familyMulti9
Device short nameC60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution
C60H3P32AB — Electrical
ParameterValue
Rated current [In]32 A at 30 °C
Number of protected poles3
Pole configuration3P
Rated operational voltage [Ue]440 V AC 50/60 Hz
Network type (AC/DC)AC
Network frequency50/60 Hz
C60H3P32AB — Protection
ParameterValue
Tripping curve codeB
Magnetic tripping limit3...5 x In
Breaking capacity (Icu)10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2
Rated service breaking capacity [Ics]15 kA conforming to IEC 60947-2 - 12...440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 60 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 AC 50/60 Hz
Energy limitation class3 conforming to IEC 60947-2
Suitable for isolationYes conforming to IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
C60H3P32AB — Mechanical
ParameterValue
9 mm pitches6
Width54 mm
Height81 mm
Depth73 mm
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Terminal connectionsTunnel type terminals25 mm² flexible Tunnel type terminals35 mm² rigid
Terminal tightening torque3.5 N.m
Comb busbar / distribution block compatibilityYES
Local signalling / indicationON/OFF indication
Contact position indicatorYes
C60H3P32AB — Environmental
ParameterValue
Operating temperature range-25...60 °C
Storage temperature range-40...70 °C
Relative humidity95 % at 55 °C

Product details

The Schneider Electric C60H3P32AB is a C60H-series miniature circuit breaker from the Multi9 range, rated 32 A at 30 °C with a B-curve trip characteristic (magnetic tripping between 3 and 5 times In). Breaking capacity is 10 kA Icu at 440 V AC per IEC 60947-2, which covers most commercial and light industrial distribution panels; the 30 kA Icu at 230–240 V AC gives headroom for high-fault utility feeds.

The 3-pole body takes 6 module pitches at 9 mm each, so it occupies 54 mm of rail width. Depth is 73 mm, height 81 mm — standard for the C60H footprint, meaning it fits existing Multi9 backplanes and enclosure gland plates without re-drilling. Tunnel terminals accept up to 35 mm² rigid or 25 mm² flexible; strip length 14 mm, torque to 3.5 N·m.

Frequently asked questions

Where can I buy C60H3P32AB and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is C60H3P32AB's breaking capacity at 440 V?

10 kA Icu at 440 V AC 50/60 Hz per IEC 60947-2. The Ics (service breaking capacity) at the same voltage is 15 kA, so the breaker can be reclosed after clearing a fault at that level.

What compliance documentation does this brand provide for C60H3P32AB?

The breaker is designed to IEC 60947-2 (breaking capacity, isolation suitability, limitation class 3) and IEC 60068-1 (tropicalisation class 2). It carries a suitability-for-isolation marking per IEC 60947-2. For specific RoHS, REACH, or UL documentation, request the manufacturer's declaration at quote time.

MPN
C60H3P32AB