Skip to main content
Schneider Electric C60H3P32AC

Schneider Electric C60H3P32AC MCB, 32A C-Curve, 3P, 10kA

MPN C60H3P32AC
Obsolete

Schneider Electric C60H, Multi9 series, C60H3P32AC miniature circuit breaker, 32 A, C-curve, 3-pole, 10 kA breaking capacity at 440 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C60H3P32AC specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
Depth73 mm
Width54 mm
Height81 mm
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

32 A C-curve MCB for distribution panels

The Schneider Electric C60H3P32AC is a C60H-series miniature circuit breaker rated at 32 A with a C-curve trip characteristic (5–10 x In magnetic tripping limit), 3 protected poles, and a 10 kA Icu breaking capacity at 440 V AC.

The C60H3P32AC delivers 30 kA Icu at 230–240 V AC and 15 kA Ics at 12–440 V AC. That Ics rating — the service breaking capacity — tells you what it can clear repeatedly without replacing the breaker. At 230 V the 30 kA Icu gives solid selectivity headroom downstream of a higher-rated upstream device, so a fault on a branch outlet won't take the whole panel down.

Snaps onto 35 mm symmetrical DIN rail, occupies 6 x 9 mm pitches (54 mm wide), with a depth of 73 mm and height of 81 mm. Tunnel-type terminals accept up to 35 mm² rigid or 25 mm² flexible cable; strip length is 14 mm and tightening torque is 3.5 N·m. That footprint fits standard distribution boards without crowding adjacent breakers or leaving too little bending radius for the incoming cable.

MPN
C60H3P32AC