Schneider Electric C60H3P32AD — 2-Pole MCB (DIN Rail)

Schneider Electric C60H3P32AD C60 MCB, 32 A, D Curve, 3P, 10

MPNC60H3P32AD
Obsolete

Schneider Electric C60H3P32AD, C60H series, Multi9 range, 3-pole miniature circuit breaker, 32 A rated current, D tripping curve, breaking capacity 10-40 kA Icu per IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C60H3P32AD — Identification
ParameterValue
Product nameC60
Product rangeC60
Series / familyMulti9
Device short nameC60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution
C60H3P32AD — Electrical
ParameterValue
Rated current [In]32 A at 40 °C
Number of protected poles3
Pole configuration3P
Rated operational voltage [Ue]440 V AC 50/60 Hz
Network type (AC/DC)AC
Network frequency50/60 Hz
C60H3P32AD — Protection
ParameterValue
Tripping curve codeD
Magnetic tripping limit10...14 x In
Breaking capacity (Icu)10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2
Rated service breaking capacity [Ics]15 kA conforming to IEC 60947-2 - 12...440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 60 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 AC 50/60 Hz
Energy limitation class3 conforming to IEC 60947-2
Suitable for isolationYes conforming to IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
C60H3P32AD — Mechanical
ParameterValue
9 mm pitches6
Width54 mm
Height81 mm
Depth73 mm
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Terminal connectionsTunnel type terminals25 mm² flexible Tunnel type terminals35 mm² rigid
Terminal tightening torque3.5 N.m
Comb busbar / distribution block compatibilityYES
Local signalling / indicationON/OFF indication
Contact position indicatorYes
C60H3P32AD — Environmental
ParameterValue
Operating temperature range-25...60 °C
Storage temperature range-40...70 °C
Relative humidity95 % at 55 °C

Product details

The C60H3P32AD is a 3-pole thermal-magnetic miniature circuit breaker from the C60H series in the Multi9 range, rated 32 A at 40 °C. The 32 A rating at 40 °C means it carries 32 A continuously in a 40 °C ambient; above that temperature, derate per IEC 60898. Breaking capacity is 10 kA Icu at 440 V AC, 15 kA at 400–415 V AC, and 30 kA at 230–240 V AC (all per IEC 60947-2). The rated service breaking capacity (Ics) is 15 kA at 12–440 V AC. Strip length is 14 mm. The fixed mounting mode and toggle control are standard for panel integration.

Compliance documentation includes IEC 60947-2 certification for breaking and service capacity, suitability for isolation per the same standard, and tropicalisation per IEC 60068-1 (2 levels).

The 73 mm depth leaves clearance for gland plates and wiring ducts in shallow enclosures. The ON/OFF indicator and contact position indicator provide local status without opening the door.

Frequently asked questions

What is the breaking capacity of C60H3P32AD at 400 V?

At 400–415 V AC, the ultimate breaking capacity (Icu) is 15 kA per IEC 60947-2. The service breaking capacity (Ics) is also 15 kA at 12–440 V AC.

What does the D curve mean for this breaker?

The D curve trips magnetically at 10–14 times the rated current (32 A), so it handles high inrush loads like motor starters or transformers without nuisance tripping. It is not intended for general lighting or resistive loads where a B or C curve would suffice.

Where can I buy C60H3P32AD and how is it quoted?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to confirm current availability and pricing — no stock or price figures are listed here.

MPN
C60H3P32AD