Skip to main content
Schneider Electric C60H3P40AC — 2-Pole MCB (DIN Rail)

Schneider Electric C60H3P40AC MCB, C Curve, 40 A, 3P, 10-40

MPNC60H3P40AC
Obsolete

Schneider Electric Multi9 C60H series, C60H3P40AC, 3-pole miniature circuit breaker, C curve, 40 A rated current, 10-40 kA breaking capacity per IEC 60947-2, thermal-magnetic trip.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C60H3P40AC — Identification
ParameterValue
Product nameC60
Product rangeC60
Series / familyMulti9
Device short nameC60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution
C60H3P40AC — Electrical
ParameterValue
Rated current [In]40 A at 30 °C
Number of protected poles3
Pole configuration3P
Rated operational voltage [Ue]440 V AC 50/60 Hz
Network type (AC/DC)AC
Network frequency50/60 Hz
C60H3P40AC — Protection
ParameterValue
Tripping curve codeC
Magnetic tripping limit5...10 x In
Breaking capacity (Icu)10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2
Rated service breaking capacity [Ics]15 kA conforming to IEC 60947-2 - 12...440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 60 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 AC 50/60 Hz
Energy limitation class3 conforming to IEC 60947-2
Suitable for isolationYes conforming to IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
C60H3P40AC — Mechanical
ParameterValue
9 mm pitches6
Width54 mm
Height81 mm
Depth73 mm
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Terminal connectionsTunnel type terminals25 mm² flexible Tunnel type terminals35 mm² rigid
Terminal tightening torque3.5 N.m
Comb busbar / distribution block compatibilityYES
Local signalling / indicationON/OFF indication
Contact position indicatorYes
C60H3P40AC — Environmental
ParameterValue
Operating temperature range-25...60 °C
Storage temperature range-40...70 °C
Relative humidity95 % at 55 °C

Product details

Occupies 6 x 9 mm pitches (54 mm wide) — standard 3-pole MCB footprint. Depth is 73 mm, height 81 mm. Tunnel terminals accept up to 35 mm² rigid or 25 mm² flexible; strip length 14 mm, torque to 3.5 N·m. The ON/OFF toggle and contact position indicator give a clear visual state at the gland plate.

Designed to IEC 60947-2 with limitation class 3 — limits let-through energy in a fault, protecting downstream equipment. Suitability for isolation confirmed per that standard. Altitude rated to 2000 m. Earth-leakage protection requires a separate Vigi block.

Frequently asked questions

Where can I buy C60H3P40AC and how do I get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote (RFQ); availability and current pricing are confirmed at quote time.

What is the breaking capacity of C60H3P40AC?

Breaking capacity varies by voltage: 30 kA Icu at 230–240 V AC, 15 kA at 400–415 V AC, 10 kA at 440 V AC, and 40 kA at 125 V DC (3P). The service breaking capacity (Ics) is 15 kA at 440 V AC.

MPN
C60H3P40AC