Skip to main content
Schneider Electric C60H3P4AD

Schneider C60H3P4AD MCB, D Curve, 4 A, 3P, 10-30 kA

MPN C60H3P4AD
Obsolete

Schneider Electric Multi9 C60H series, C60H3P4AD miniature circuit breaker, 3-pole, D curve, 4 A rated current at 40 °C, breaking capacity 10-30 kA.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C60H3P4AD specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
Depth73 mm
Width54 mm
Height81 mm
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric C60H3P4AD is a Multi9 C60H miniature circuit breaker (MCB) with a D tripping curve, 4 A rated current at 40 °C, and 3 protected poles. The magnetic trip threshold of 10...14 x In means it tolerates starting surges up to 56 A peak before instantaneously opening, while the thermal-magnetic element handles sustained overloads.

This breaker carries a 30 kA Icu at 230...240 V AC and 15 kA Icu at 400...415 V AC, both per IEC 60947-2. For a 4 A MCB in a typical 230/400 V panel, that SCCR headroom allows full selectivity with upstream devices rated for 25 kA or higher—no need to oversize the main breaker just to protect this branch. At 125 V DC, the 2P series configuration gives 25 kA Icu; 3P gives 40 kA Icu, useful for DC distribution in telecom or UPS cabinets.

The 54 mm width (6 x 9 mm pitches) and 73 mm depth leave room for adjacent breakers and tunnel-type terminals that accept up to 25 mm² rigid or 16 mm² flexible conductors. The toggle actuator provides local ON/OFF indication and a contact position indicator confirms isolation status per IEC 60947-2.

MPN
C60H3P4AD