Skip to main content
Schneider Electric C60H3P4AD — 2-Pole MCB (DIN Rail)

Schneider C60H3P4AD MCB, D Curve, 4 A, 3P, 10-30 kA

MPNC60H3P4AD
Obsolete

Schneider Electric Multi9 C60H series, C60H3P4AD miniature circuit breaker, 3-pole, D curve, 4 A rated current at 40 °C, breaking capacity 10-30 kA.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C60H3P4AD — Identification
ParameterValue
Product nameC60
Product rangeC60
Series / familyMulti9
Device short nameC60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution
C60H3P4AD — Electrical
ParameterValue
Rated current [In]4 A at 40 °C
Number of protected poles3
Pole configuration3P
Rated operational voltage [Ue]440 V AC 50/60 Hz
Network type (AC/DC)AC
Network frequency50/60 Hz
C60H3P4AD — Protection
ParameterValue
Tripping curve codeD
Magnetic tripping limit10...14 x In
Breaking capacity (Icu)10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2
Rated service breaking capacity [Ics]15 kA conforming to IEC 60947-2 - 12...440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 60 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 AC 50/60 Hz
Energy limitation class3 conforming to IEC 60947-2
Suitable for isolationYes conforming to IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
C60H3P4AD — Mechanical
ParameterValue
9 mm pitches6
Width54 mm
Height81 mm
Depth73 mm
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Terminal connectionsTunnel type terminals16 mm² flexible Tunnel type terminals25 mm² rigid
Terminal tightening torque2 N.m
Comb busbar / distribution block compatibilityYES
Local signalling / indicationON/OFF indication
Contact position indicatorYes
C60H3P4AD — Environmental
ParameterValue
Operating temperature range-25...60 °C
Storage temperature range-40...70 °C
Relative humidity95 % at 55 °C

Product details

The Schneider Electric C60H3P4AD is a Multi9 C60H miniature circuit breaker (MCB) with a D tripping curve, 4 A rated current at 40 °C, and 3 protected poles. The magnetic trip threshold of 10...14 x In means it tolerates starting surges up to 56 A peak before instantaneously opening, while the thermal-magnetic element handles sustained overloads.

This breaker carries a 30 kA Icu at 230...240 V AC and 15 kA Icu at 400...415 V AC, both per IEC 60947-2. For a 4 A MCB in a typical 230/400 V panel, that SCCR headroom allows full selectivity with upstream devices rated for 25 kA or higher—no need to oversize the main breaker just to protect this branch. At 125 V DC, the 2P series configuration gives 25 kA Icu; 3P gives 40 kA Icu, useful for DC distribution in telecom or UPS cabinets.

The 54 mm width (6 x 9 mm pitches) and 73 mm depth leave room for adjacent breakers and tunnel-type terminals that accept up to 25 mm² rigid or 16 mm² flexible conductors. The toggle actuator provides local ON/OFF indication and a contact position indicator confirms isolation status per IEC 60947-2.

Frequently asked questions

What is the breaking capacity of C60H3P4AD?

The C60H3P4AD has a rated breaking capacity (Icu) of 30 kA at 230...240 V AC, 15 kA at 400...415 V AC, and 10 kA at 440 V AC, all per IEC 60947-2. At 125 V DC, it achieves 25 kA (2P) or 40 kA (3P).

What does the D curve mean on this MCB?

The D curve means the magnetic trip threshold is 10...14 x In (40...56 A for this 4 A breaker). It is intended for circuits with high inrush currents like motors, transformers, or discharge lighting, where a B or C curve would trip on startup.

Where can I buy C60H3P4AD?

The C60H3P4AD is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What compliance documentation is available for C60H3P4AD?

The breaker is certified to IEC 60947-2 for breaking capacity, isolation suitability, and limitation class 3. It also conforms to IEC 60068-1 for tropicalisation (2 levels). RoHS, REACH, and UL documentation may be available from the manufacturer; verify specific compliance needs at order.

MPN