Schneider C60H3P50AC MCB, 50A 3P C-Curve, 10kA

MPN C60H3P50AC
Obsolete

Schneider Electric Multi9 C60, C60H3P50AC, 3-pole miniature circuit breaker, 50 A rated, C-curve, 10 kA breaking capacity at 440 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C60H3P50AC specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
Depth73 mm
Width54 mm
Height81 mm
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

What this MCB does in the panel

The Schneider Electric C60H3P50AC is a 3-pole C60H miniature circuit breaker rated 50 A at 30 °C, with a C-curve trip characteristic (magnetic tripping between 5 and 10 times In). At 230…240 V AC the C60H3P50AC interrupts 30 kA; at 400…415 V AC it handles 15 kA; at its rated operational voltage of 440 V AC it breaks 10 kA. All figures are Icu per IEC 60947-2, so the standard certifies the breaker can make and break a fault once at that level and still be serviceable. The thermal-magnetic trip unit handles overloads via a bimetal strip (thermal) and short-circuits via a solenoid (magnetic). The C-curve means the magnetic trip fires between 5× and 10× In — 250 A to 500 A for this 50 A unit — which suits lighting, distribution, and general-purpose loads where inrush is moderate but not as high as motor-start.

The ON/OFF toggle gives local indication, and a contact position indicator confirms the main contacts are open — IEC 60947-2 certified for isolation when the handle is in the OFF position.

Tropicalisation level 2 per IEC 60068-1, limitation class 3 per IEC 60947-2. Operating temperature range -25…60 °C, storage -40…70 °C. Relative humidity 95% at 55 °C. Altitude limit 2000 m. The MCB carries IEC 60947-2 certification for the breaking capacity and isolation claims listed above.