Obsolete

Schneider Electric Multi9 C60, C60H3P50AC, 3-pole miniature circuit breaker, 50 A rated, C-curve, 10 kA breaking capacity at 440 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C60H3P50AC — Identification
ParameterValue
Product nameC60
Product rangeC60
Series / familyMulti9
Device short nameC60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution
C60H3P50AC — Electrical
ParameterValue
Rated current [In]50 A at 30 °C
Number of protected poles3
Pole configuration3P
Rated operational voltage [Ue]440 V AC 50/60 Hz
Network type (AC/DC)AC
Network frequency50/60 Hz
C60H3P50AC — Protection
ParameterValue
Tripping curve codeC
Magnetic tripping limit5...10 x In
Breaking capacity (Icu)10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2
Rated service breaking capacity [Ics]15 kA conforming to IEC 60947-2 - 12...440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 60 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 AC 50/60 Hz
Energy limitation class3 conforming to IEC 60947-2
Suitable for isolationYes conforming to IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
C60H3P50AC — Mechanical
ParameterValue
9 mm pitches6
Width54 mm
Height81 mm
Depth73 mm
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Terminal connectionsTunnel type terminals25 mm² flexible Tunnel type terminals35 mm² rigid
Terminal tightening torque3.5 N.m
Comb busbar / distribution block compatibilityYES
Local signalling / indicationON/OFF indication
Contact position indicatorYes
C60H3P50AC — Environmental
ParameterValue
Operating temperature range-25...60 °C
Storage temperature range-40...70 °C
Relative humidity95 % at 55 °C

Product details

What this MCB does in the panel

The Schneider Electric C60H3P50AC is a 3-pole C60H miniature circuit breaker rated 50 A at 30 °C, with a C-curve trip characteristic (magnetic tripping between 5 and 10 times In). At 230…240 V AC the C60H3P50AC interrupts 30 kA; at 400…415 V AC it handles 15 kA; at its rated operational voltage of 440 V AC it breaks 10 kA. All figures are Icu per IEC 60947-2, so the standard certifies the breaker can make and break a fault once at that level and still be serviceable. The thermal-magnetic trip unit handles overloads via a bimetal strip (thermal) and short-circuits via a solenoid (magnetic). The C-curve means the magnetic trip fires between 5× and 10× In — 250 A to 500 A for this 50 A unit — which suits lighting, distribution, and general-purpose loads where inrush is moderate but not as high as motor-start.

The ON/OFF toggle gives local indication, and a contact position indicator confirms the main contacts are open — IEC 60947-2 certified for isolation when the handle is in the OFF position.

Tropicalisation level 2 per IEC 60068-1, limitation class 3 per IEC 60947-2. Operating temperature range -25…60 °C, storage -40…70 °C. Relative humidity 95% at 55 °C. Altitude limit 2000 m. The MCB carries IEC 60947-2 certification for the breaking capacity and isolation claims listed above.

Frequently asked questions

Where can I buy C60H3P50AC?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of C60H3P50AC at 400 V?

At 400…415 V AC 50/60 Hz the C60H3P50AC has a rated ultimate breaking capacity (Icu) of 15 kA per IEC 60947-2.

What does the C-curve mean on this MCB?

The C-curve means the magnetic trip operates between 5 and 10 times the rated current (250–500 A for this 50 A unit), which suits general-purpose distribution and lighting loads with moderate inrush.

What compliance documentation does this brand provide for C60H3P50AC?

The MCB is certified to IEC 60947-2 for breaking capacity and isolation. Tropicalisation conforms to IEC 60068-1. RoHS and REACH compliance documentation is available through the standard Schneider Electric channels.