Skip to main content
Schneider Electric C60H3P50AD — 2-Pole MCB (DIN Rail)

Schneider C60H3P50AD C60 MCB, 3P, 50 A, D Curve, 10-14x In

MPNC60H3P50AD
Obsolete

Schneider Electric, Multi9 series, C60H3P50AD miniature circuit breaker, 3-pole, 50 A, D curve, 10-14 x In magnetic trip, 10 kA Icu at 440 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C60H3P50AD — Identification
ParameterValue
Product nameC60
Product rangeC60
Series / familyMulti9
Device short nameC60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution
C60H3P50AD — Electrical
ParameterValue
Rated current [In]50 A at 40 °C
Number of protected poles3
Pole configuration3P
Rated operational voltage [Ue]440 V AC 50/60 Hz
Network type (AC/DC)AC
Network frequency50/60 Hz
C60H3P50AD — Protection
ParameterValue
Tripping curve codeD
Magnetic tripping limit10...14 x In
Breaking capacity (Icu)10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2
Rated service breaking capacity [Ics]15 kA conforming to IEC 60947-2 - 12...440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 60 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 AC 50/60 Hz
Energy limitation class3 conforming to IEC 60947-2
Suitable for isolationYes conforming to IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
C60H3P50AD — Mechanical
ParameterValue
9 mm pitches6
Width54 mm
Height81 mm
Depth73 mm
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Terminal connectionsTunnel type terminals25 mm² flexible Tunnel type terminals35 mm² rigid
Terminal tightening torque3.5 N.m
Comb busbar / distribution block compatibilityYES
Local signalling / indicationON/OFF indication
Contact position indicatorYes
C60H3P50AD — Environmental
ParameterValue
Operating temperature range-25...60 °C
Storage temperature range-40...70 °C
Relative humidity95 % at 55 °C

Product details

The Schneider Electric C60H3P50AD is a 3-pole C60H miniature circuit breaker from the Multi9 range, rated 50 A at 40 °C with a D trip curve. The D curve's magnetic tripping limit of 10...14 x In means it handles high inrush loads — motor starting, transformer energization, or welding equipment — without nuisance tripping on the magnetic element, while still clearing hard faults. Breaking capacity is 10 kA Icu at 440 V AC (IEC 60947-2), with higher ratings at lower voltages: 30 kA at 230...240 V AC and 25 kA at 125 V DC (2P). For distribution panels feeding motor control centers or general branch circuits, this gives solid fault-clearing headroom.

Fixed mounting, tunnel-type terminals accept up to 35 mm² rigid or 25 mm² flexible wire; strip length 14 mm, torque to 3.5 N·m. The 6-pitch (54 mm wide) footprint fits a standard 3-pole MCB slot.

Frequently asked questions

What is the C60H3P50AD rated current and trip curve?

Rated 50 A at 40 °C with a D curve. The magnetic trip operates at 10...14 x In (500...700 A), designed for high-inrush loads like motors and transformers.

What is the breaking capacity of the C60H3P50AD?

10 kA Icu at 440 V AC per IEC 60947-2. At 230...240 V AC it rises to 30 kA Icu. The Ics service breaking capacity is 15 kA at 440 V AC, allowing reclosure after a fault at that level.

Where can I buy the C60H3P50AD and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What compliance documentation is available for the C60H3P50AD?

The breaker carries IEC 60947-2 certification for breaking capacity and isolation suitability. Tropicalisation per IEC 60068-1 (class 2) and limitation class 3 per IEC 60947-2 are specified. RoHS and REACH compliance documentation is typically available from Schneider Electric upon request.

MPN