Schneider Electric C60H4P16AB

Schneider C60H4P16AB MCB, B Curve 16 A 4P, 10 kA

MPN C60H4P16AB
Obsolete

Schneider Electric C60H4P16AB, Multi9 C60H series, miniature circuit breaker, 4-pole, B-curve, 16 A, 10 kA Icn at 230/400 V AC, 72 x 81 x 73 mm.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C60H4P16AB specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage12...440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity10 kA Icn at 230/400 V AC 50/60 Hz conforming to EN 60898 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2 50 kA Icu at 250 V DC 4P conforming to IEC 60947-2
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
Depth73 mm
Width72 mm
Height81 mm
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

Integrator's note on the C60H4P16AB

The Schneider Electric C60H4P16AB is a 4-pole miniature circuit breaker from the Multi9 C60H series, rated 16 A with a B-curve trip characteristic (3 to 5 x In magnetic trip). It carries a 10 kA Icn breaking capacity at 230/400 V AC per EN 60898, and higher Icu ratings per IEC 60947-2 — 15 kA at 400–415 V AC, 30 kA at 230–240 V AC. The dual standard means it qualifies for both residential distribution boards (EN 60898) and industrial panel applications (IEC 60947-2), so you can spec it into a commercial MCC or a branch panel without re-certifying the assembly. The 72 mm width (8 x 9 mm pitches) and 73 mm depth fit standard enclosure cutouts — no odd footprint to accommodate.

Do not use it for motor starting; that calls for a C or D curve. The 10 kA Icn at 230/400 V AC is the rated short-circuit capacity under EN 60898; the higher Icu values under IEC 60947-2 (up to 50 kA at 250 V DC for the 4P configuration) give you headroom for industrial fault levels. The Ics (service breaking capacity) is 7.5 kA at 230/400 V AC per EN 60898 — meaning after clearing a fault at that level, the breaker is still usable, not wrecked. Rated operational voltage spans 12–440 V AC 50/60 Hz, and the insulation voltage is 500 V AC. The 4-pole version also carries DC ratings: 25 kA Icu at 125 V DC (2P in series) and 40 kA at 125 V DC (3P in series). That DC capability is useful for battery-backed buswork or UPS distribution panels.

Deployment context

The 4-pole version handles three-phase plus neutral, or four-phase distribution in DC applications. Ambient operating range is -25 to 60 °C, with 95% humidity tolerance at 55 °C and tropicalisation class 2 per IEC 60068-1 — fine for unventilated enclosures in warm climates.

MPN
C60H4P16AB