Schneider Electric C60H4P2AD — 2-Pole MCB (DIN Rail)

Schneider Electric C60H4P2AD MCB, 4P, D Curve, 2 A, 10 kA

MPNC60H4P2AD
Obsolete

Schneider Electric Multi9 C60H, miniature circuit breaker, 4P, D curve, 2 A at 40 °C, 10 kA Icn, thermal-magnetic trip, 35 mm DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C60H4P2AD — Identification
ParameterValue
Product nameC60
Product rangeC60
Series / familyMulti9
Device short nameC60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution
C60H4P2AD — Electrical
ParameterValue
Rated current [In]2 A at 40 °C
Number of protected poles4
Pole configuration4P
Rated operational voltage [Ue]12...440 V AC 50/60 Hz
Network type (AC/DC)AC DC
Network frequency50/60 Hz
C60H4P2AD — Protection
ParameterValue
Tripping curve codeD
Magnetic tripping limit10...14 x In
Breaking capacity (Icu)10 kA Icn at 230/400 V AC 50/60 Hz conforming to EN 60898 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2 50 kA Icu at 250 V DC 4P conforming to IEC 60947-2
Rated service breaking capacity [Ics]7.5 kA conforming to EN 60898 - 230/400 V AC 50/60 Hz 15 kA conforming to IEC 60947-2 - 230...240 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 - 440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 400...415 V AC 50/60 Hz
Energy limitation class3 conforming to IEC 60947-2
Suitable for isolationYes conforming to IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
C60H4P2AD — Mechanical
ParameterValue
9 mm pitches8
Width72 mm
Height81 mm
Depth73 mm
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Terminal connectionsTunnel type terminals16 mm² flexible Tunnel type terminals25 mm² rigid
Terminal tightening torquePower circuit: 2 N.m upside 2 N.m downside
Comb busbar / distribution block compatibilityNO
Local signalling / indicationON/OFF indication
Contact position indicatorYes
C60H4P2AD — Environmental
ParameterValue
Operating temperature range-25...60 °C
Storage temperature range-40...70 °C
Relative humidity95 % at 55 °C
C60H4P2AD — Approvals
ParameterValue
Standards / complianceIEC 60947-2 EN 60898

Product details

The Schneider Electric C60H4P2AD is a 4-pole miniature circuit breaker from the Multi9 C60H range, rated 2 A at 40 °C with a D tripping curve (magnetic trip 10–14 x In). It carries a 10 kA Icn breaking capacity at 230/400 V AC per EN 60898, and higher Icu ratings per IEC 60947-2: 15 kA at 400–415 V AC, 30 kA at 230–240 V AC, and 40 kA at 125 V DC (3P) or 50 kA at 250 V DC (4P). That spread covers both AC distribution and DC control circuits in the same footprint — useful when a panel mixes line and low-voltage DC loads.

At 73 mm deep and 81 mm tall, it fits standard distribution boards without crowding the gland plate.

Selectivity and coordination

The 2 A rating is a fast mover in control transformer secondary protection and small motor branch circuits.

Frequently asked questions

Where can I buy C60H4P2AD and how do I get a price?

This part is sourced and quoted to order through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time.

What is C60H4P2AD's listed depth?

The C60H4P2AD has a depth of 73 mm, fitting standard distribution board enclosures.

What compliance documentation does this breaker carry?

It is certified to IEC 60947-2 and EN 60898, with suitability for isolation per IEC 60947-2. Tropicalisation class 2 per IEC 60068-1 covers high-humidity environments.

MPN
C60H4P2AD