Skip to main content
Schneider Electric C60H4P32AB — 2-Pole MCB (DIN Rail)

C60H4P32AB Miniature Circuit Breaker, 32 A, Curve B, 10 kA,

MPNC60H4P32AB
Obsolete

Schneider Electric Multi9 C60H, miniature circuit-breaker, C60H4P32AB, 4P, 32 A, B curve, 10 kA Icn at 230/400 V AC, 35 mm DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C60H4P32AB — Identification
ParameterValue
Product nameC60
Product rangeC60
Series / familyMulti9
Device short nameC60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution
C60H4P32AB — Electrical
ParameterValue
Rated current [In]32 A at 30 °C
Number of protected poles4
Pole configuration4P
Rated operational voltage [Ue]12...440 V AC 50/60 Hz
Network type (AC/DC)DC AC
Network frequency50/60 Hz
C60H4P32AB — Protection
ParameterValue
Tripping curve codeB
Magnetic tripping limit3...5 x In
Breaking capacity (Icu)10 kA Icn at 230/400 V AC 50/60 Hz conforming to EN 60898 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2 50 kA Icu at 250 V DC 4P conforming to IEC 60947-2
Rated service breaking capacity [Ics]7.5 kA conforming to EN 60898 - 230/400 V AC 50/60 Hz 15 kA conforming to IEC 60947-2 - 230...240 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 - 440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 400...415 V AC 50/60 Hz
Energy limitation class3 conforming to IEC 60947-2
Suitable for isolationYes conforming to IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
C60H4P32AB — Mechanical
ParameterValue
9 mm pitches8
Width72 mm
Height81 mm
Depth73 mm
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Terminal connectionsTunnel type terminals25 mm² flexible Tunnel type terminals35 mm² rigid
Terminal tightening torquePower circuit: 3.5 N.m upside 3.5 N.m downside
Comb busbar / distribution block compatibilityNO
Local signalling / indicationON/OFF indication
Contact position indicatorYes
C60H4P32AB — Environmental
ParameterValue
Operating temperature range-25...60 °C
Storage temperature range-40...70 °C
Relative humidity95 % at 55 °C
C60H4P32AB — Approvals
ParameterValue
Standards / complianceIEC 60947-2 EN 60898

Product details

The C60H4P32AB is a 4-pole miniature circuit-breaker from the Schneider Multi9 C60H series, rated 32 A at 30 °C with a B tripping curve (3–5 x In magnetic trip). It breaks up to 10 kA Icn under EN 60898 at 230/400 V AC, and up to 30 kA Icu under IEC 60947-2 at 230–240 V AC — covering both residential and industrial fault-current requirements.

The C60H4P32AB's Ics (service breaking capacity) is 7.5 kA at 230/400 V per EN 60898, and 15 kA at 230–240 V per IEC 60947-2. That means after clearing a fault at these levels the breaker remains usable — not just safe but functional — which matters for selectivity studies and downstream coordination in a multi-level distribution board.

Occupies 8 x 9 mm pitches (72 mm wide), 81 mm tall, 73 mm deep.

Listed as current production (active lifecycle stage). The C60H series is a long-running platform; no official successor has been announced.

Frequently asked questions

What is the breaking capacity of C60H4P32AB?

The C60H4P32AB has a rated breaking capacity of 10 kA Icn at 230/400 V AC per EN 60898, and up to 30 kA Icu at 230–240 V AC per IEC 60947-2. Service breaking capacity (Ics) is 7.5 kA at 230/400 V per EN 60898.

What is the tripping curve and magnetic threshold?

B curve, with magnetic tripping between 3 and 5 times the rated current (In). That means for a 32 A breaker, the magnetic trip activates between 96 A and 160 A, suited for resistive and general-purpose loads where inrush is low.

Where can I buy the C60H4P32AB?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.