Skip to main content
Schneider Electric C60H4P32AC

Schneider C60H4P32AC MCB, C-Curve 32A 4P, 10kA

MPN C60H4P32AC
Obsolete

Schneider Electric Multi9 C60H, C60H4P32AC, miniature circuit breaker, 4-pole, C-curve, 32 A rated current, 10 kA breaking capacity per EN 60898, thermal-magnetic trip unit, 35 mm DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C60H4P32AC specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage12...440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity10 kA Icn at 230/400 V AC 50/60 Hz conforming to EN 60898 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2 50 kA Icu at 250 V DC 4P conforming to IEC 60947-2
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
Depth73 mm
Width72 mm
Height81 mm
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The C60H4P32AC is a 4-pole miniature circuit breaker from Schneider Electric's Multi9 C60 range, rated 32 A at 30 °C with a C-curve magnetic trip (5 to 10 x In). The 10 kA Icn at 230/400 V AC per EN 60898 is the rated short-circuit capacity for the breaker under standard conditions; the higher Icu values (up to 30 kA at 230–240 V AC per IEC 60947-2) cover industrial fault levels. For a 4-pole breaker, the 32 A rating and C-curve suit sub-distribution boards where the downstream load includes small motors, lighting, and socket outlets. The thermal-magnetic trip unit combines a bimetal element for overload protection and a solenoid for short-circuit response. The magnetic threshold at 5–10 x In means the breaker holds through transformer inrush and motor starting current without nuisance tripping, but clears fast on a hard fault.

The toggle control provides local ON/OFF indication and a contact position indicator confirms the state of the moving contacts for isolation verification. The tropicalisation treatment (class 2 per IEC 60068-1) and 95 % relative humidity rating at 55 °C make it suitable for unconditioned electrical rooms and outdoor-rated enclosures in humid climates.

Compliance documentation includes EN 60898 (household and similar installations) and IEC 60947-2 (industrial) standards. The limitation class 3 per IEC 60947-2 indicates energy-limiting performance that reduces let-through energy on faults.

MPN
C60H4P32AC