Skip to main content
Schneider Electric C60H4P3AC

Schneider Electric C60H4P3AC MCB, C-Curve 3A 4P, 10 kA

MPN C60H4P3AC
Obsolete

Schneider Electric Multi9 C60H, miniature circuit breaker, C60H4P3AC, 4P, 3 A, C-curve, 10 kA Icn at 230/400 V AC, 35 mm DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C60H4P3AC specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage12...440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity10 kA Icn at 230/400 V AC 50/60 Hz conforming to EN 60898 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2 50 kA Icu at 250 V DC 4P conforming to IEC 60947-2
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
Depth73 mm
Width72 mm
Height81 mm
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric C60H4P3AC is a 4-pole miniature circuit breaker from the Multi9 C60 range, rated 3 A with a C-curve trip characteristic (5...10 x In magnetic tripping limit). It carries a 10 kA Icn breaking capacity at 230/400 V AC per EN 60898, and higher Icu ratings under IEC 60947-2 — up to 50 kA at 250 V DC for the 4P configuration. The thermal-magnetic trip unit protects distribution circuits in commercial and industrial panels.

Occupies 8 x 9 mm pitches (72 mm wide, 81 mm tall, 73 mm deep). The toggle handle provides local ON/OFF indication and a contact position indicator confirms isolation status per IEC 60947-2.

Breaking capacity and duty ratings

The C-curve (5...10 x In) suits mixed resistive and inductive loads where moderate inrush is expected — typical for distribution sub-circuits feeding contactor coils, small motors, or lighting banks. The 10 kA Icn at 230/400 V AC meets EN 60898 for domestic/commercial installations; the IEC 60947-2 Icu ratings extend to 15 kA at 400...415 V AC and 30 kA at 230...240 V AC. For DC applications, the 4P series connection yields 40 kA Icu at 125 V DC and 50 kA at 250 V DC. The Ics (service breaking capacity) is 7.5 kA at 230/400 V AC per EN 60898, meaning the breaker can be reclosed after clearing a fault at that level without replacement.

MPN
C60H4P3AC