Skip to main content
Schneider Electric C60H4P50AD

Schneider C60H4P50AD MCB, 50A D-curve, 4P, Multi9

MPN C60H4P50AD
Obsolete

Schneider Electric Multi9 C60H series, C60H4P50AD miniature circuit breaker, 4-pole, D-curve, 50 A rated, 10 kA breaking capacity per EN 60898.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C60H4P50AD specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage12...440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
Depth73 mm
Width72 mm
Height81 mm
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The C60H4P50AD is a 4-pole miniature circuit breaker from the Schneider Multi9 C60 range, rated 50 A at 40 °C with a D-curve magnetic trip (10–14 × In). That D-curve means it tolerates the high inrush of motor, transformer, or welding loads without nuisance tripping — the magnetic release only fires at 10 to 14 times the rated current, so a 50 A breaker won't pop on a 300 A motor start that clears in a few cycles. The 10 kA Icn at 230/400 V AC per EN 60898 is the standard household/commercial interrupting rating; the IEC 60947-2 ratings go higher (up to 50 kA Icu at 250 V DC 4P) for industrial panel duty. Thermal-magnetic trip technology covers both overload (thermal bimetal) and short-circuit (solenoid) protection in one unit.

Snaps onto 35 mm symmetrical DIN rail — standard for any distribution board or industrial enclosure. At 72 mm wide (8 × 9 mm pitches), it occupies four modular spaces, so check your rail fill before slotting it in. The fixed mounting mode and toggle control are straightforward for panel builders; ON/OFF indication and a contact position indicator give a quick visual on status without needing a meter.

EN 60898 covers the household/residential rating (10 kA Icn at 230/400 V), while IEC 60947-2 provides the industrial performance grades (higher Icu values, isolation suitability).

MPN
C60H4P50AD