Schneider Electric C60H4P63AC

Schneider Electric C60H4P63AC MCB, C Curve, 63 A, 4P, Multi9

MPN C60H4P63AC
Obsolete

Schneider Electric Multi9 C60H C60H4P63AC, miniature circuit breaker, 4P, 63 A, C curve, 10 kA Icn at 230/400 V AC, thermal-magnetic trip, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C60H4P63AC specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage12...440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity10 kA Icn at 230/400 V AC 50/60 Hz conforming to EN 60898 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2 50 kA Icu at 250 V DC 4P conforming to IEC 60947-2
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
Depth73 mm
Width72 mm
Height81 mm
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The C60H4P63AC is a 4-pole miniature circuit breaker from the Multi9 C60 range, rated 63 A at 30 °C with a C curve (magnetic trip 5–10 × In). The 10 kA Icn at 230/400 V AC (EN 60898) is the standard interrupting rating for a residential or light commercial distribution board; the higher Icu ratings under IEC 60947-2 (up to 50 kA at 250 V DC 4P) tell you it can also serve in an industrial panel where the prospective fault current is higher, as long as the service breaking capacity (Ics) is coordinated downstream. The 4-pole version isolates all live conductors in a three-phase plus neutral system — common for TN or TT earthing schemes where you want full disconnection.

The 72 mm width (8 × 9 mm pitches) fits standard distribution board cutouts. The toggle provides local ON/OFF indication and a contact position indicator confirms isolation status — useful for lockout/tagout verification. Separate earth-leakage block (Vigi) can be added on the downstream side if RCD protection is needed.

MPN
C60H4P63AC