Schneider Electric C60H4P63AD

Schneider Electric C60H4P63AD MCB, D Curve, 63 A, 4P, Multi9

MPN C60H4P63AD
Obsolete

Schneider Electric Multi9 C60H series, C60H4P63AD, 4-pole miniature circuit breaker, D curve, 63 A rated current at 40 °C, thermal-magnetic trip, breaking capacity 10 kA Icn (EN 60898) at 230/400 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C60H4P63AD specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage12...440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity10 kA Icn at 230/400 V AC 50/60 Hz conforming to EN 60898 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2 50 kA Icu at 250 V DC 4P conforming to IEC 60947-2
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
Depth73 mm
Width72 mm
Height81 mm
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The C60H4P63AD is a 4-pole miniature circuit breaker from the Schneider Multi9 C60H series, rated 63 A at 40 °C with a D tripping curve. The 4-pole version (4P) switches all four poles simultaneously, used on three-phase plus neutral circuits or DC applications where full isolation is required. Breaking capacity is the key safety spec: 10 kA Icn at 230/400 V AC per EN 60898, and higher Icu values per IEC 60947-2 — up to 50 kA at 250 V DC for the 4-pole configuration. The Icn rating (10 kA) is the standard for distribution boards under EN 60898; the Icu ratings (15 kA at 400...415 V AC, 30 kA at 230...240 V AC) apply when the breaker is specified to IEC 60947-2 for industrial panels. The Ics (service breaking capacity) ranges from 5 kA to 15 kA depending on voltage — this is the capacity the breaker can clear and still be reused, not just survive once.

At 72 mm wide (8 x 9 mm pitches), it occupies 8 module spaces in a distribution board or enclosure. Depth is 73 mm, height 81 mm — check gland plate clearance if the enclosure is shallow. The fixed mounting mode means it clips onto the rail and stays put — no DIN-rail adapter or additional bracket needed.

Dual-certified to IEC 60947-2 (industrial) and EN 60898 (domestic/similar) — the IEC 60947-2 rating governs industrial panel use; EN 60898 applies when installed in distribution boards to the residential/commercial standard. Relative humidity tolerance is 95 % at 55 °C. Maximum operating altitude is 2000 m without derating. Earth-leakage protection requires a separate residual current block (not integrated).

MPN