Skip to main content
Schneider Electric C60H4P63AD — 2-Pole MCB (DIN Rail)

Schneider Electric C60H4P63AD MCB, D Curve, 63 A, 4P, Multi9

MPNC60H4P63AD
Obsolete

Schneider Electric Multi9 C60H series, C60H4P63AD, 4-pole miniature circuit breaker, D curve, 63 A rated current at 40 °C, thermal-magnetic trip, breaking capacity 10 kA Icn (EN 60898) at 230/400 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C60H4P63AD — Identification
ParameterValue
Product nameC60
Product rangeC60
Series / familyMulti9
Device short nameC60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution
C60H4P63AD — Electrical
ParameterValue
Rated current [In]63 A at 40 °C
Number of protected poles4
Pole configuration4P
Rated operational voltage [Ue]12...440 V AC 50/60 Hz
Network type (AC/DC)DC AC
Network frequency50/60 Hz
C60H4P63AD — Protection
ParameterValue
Tripping curve codeD
Magnetic tripping limit10...14 x In
Breaking capacity (Icu)10 kA Icn at 230/400 V AC 50/60 Hz conforming to EN 60898 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2 50 kA Icu at 250 V DC 4P conforming to IEC 60947-2
Rated service breaking capacity [Ics]7.5 kA conforming to EN 60898 - 230/400 V AC 50/60 Hz 15 kA conforming to IEC 60947-2 - 230...240 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 - 440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 400...415 V AC 50/60 Hz
Energy limitation class3 conforming to IEC 60947-2
Suitable for isolationYes conforming to IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
C60H4P63AD — Mechanical
ParameterValue
9 mm pitches8
Width72 mm
Height81 mm
Depth73 mm
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Terminal connectionsTunnel type terminals25 mm² flexible Tunnel type terminals35 mm² rigid
Terminal tightening torquePower circuit: 3.5 N.m upside 3.5 N.m downside
Comb busbar / distribution block compatibilityNO
Local signalling / indicationON/OFF indication
Contact position indicatorYes
C60H4P63AD — Environmental
ParameterValue
Operating temperature range-25...60 °C
Storage temperature range-40...70 °C
Relative humidity95 % at 55 °C
C60H4P63AD — Approvals
ParameterValue
Standards / complianceIEC 60947-2 EN 60898

Product details

The C60H4P63AD is a 4-pole miniature circuit breaker from the Schneider Multi9 C60H series, rated 63 A at 40 °C with a D tripping curve. The 4-pole version (4P) switches all four poles simultaneously, used on three-phase plus neutral circuits or DC applications where full isolation is required. Breaking capacity is the key safety spec: 10 kA Icn at 230/400 V AC per EN 60898, and higher Icu values per IEC 60947-2 — up to 50 kA at 250 V DC for the 4-pole configuration. The Icn rating (10 kA) is the standard for distribution boards under EN 60898; the Icu ratings (15 kA at 400...415 V AC, 30 kA at 230...240 V AC) apply when the breaker is specified to IEC 60947-2 for industrial panels. The Ics (service breaking capacity) ranges from 5 kA to 15 kA depending on voltage — this is the capacity the breaker can clear and still be reused, not just survive once.

At 72 mm wide (8 x 9 mm pitches), it occupies 8 module spaces in a distribution board or enclosure. Depth is 73 mm, height 81 mm — check gland plate clearance if the enclosure is shallow. The fixed mounting mode means it clips onto the rail and stays put — no DIN-rail adapter or additional bracket needed.

Dual-certified to IEC 60947-2 (industrial) and EN 60898 (domestic/similar) — the IEC 60947-2 rating governs industrial panel use; EN 60898 applies when installed in distribution boards to the residential/commercial standard. Relative humidity tolerance is 95 % at 55 °C. Maximum operating altitude is 2000 m without derating. Earth-leakage protection requires a separate residual current block (not integrated).

Frequently asked questions

How do I get current pricing and availability for C60H4P63AD?

The C60H4P63AD is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit a request for quote to get a firm price and lead time for your quantity.

What is the closest alternative to C60H4P63AD in the same family?

Within the Multi9 C60H series, the closest alternative would be a different current rating or pole count — for example, the C60H4P40AD (40 A, D curve, 4P) or C60H4P50AD (50 A, D curve, 4P). These share the same physical footprint, DIN-rail mount, and breaking capacity ratings. For a different curve, the C60H4P63AC (C curve, 63 A, 4P) offers the same current but with a lower magnetic trip threshold (5-10 x In) for general-purpose loads without high inrush.

What is C60H4P63AD's listed depth?

The depth is 73 mm. Combined with a width of 72 mm (8 x 9 mm pitches) and height of 81 mm, it fits standard distribution board cutouts and enclosures with adequate gland plate clearance.

What compliance documentation does Schneider provide for C60H4P63AD?

The breaker is certified to IEC 60947-2 and EN 60898. It carries tropicalisation class 2 per IEC 60068-1. For RoHS, REACH, and UL documentation, Schneider Electric provides declarations of conformity and material compliance sheets through their product documentation portal — these are typically available for download by order code.

MPN
C60H4P63AD