C60H4P6AC — Identification
ParameterValue
Product nameC60
Product rangeC60
Series / familyMulti9
Device short nameC60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution
C60H4P6AC — Electrical
ParameterValue
Rated current [In]6 A at 30 °C
Number of protected poles4
Pole configuration4P
Rated operational voltage [Ue]12...440 V AC 50/60 Hz
Network type (AC/DC)AC DC
Network frequency50/60 Hz
C60H4P6AC — Protection
ParameterValue
Tripping curve codeC
Magnetic tripping limit5...10 x In
Breaking capacity (Icu)10 kA Icn at 230/400 V AC 50/60 Hz conforming to EN 60898 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2 50 kA Icu at 250 V DC 4P conforming to IEC 60947-2
Rated service breaking capacity [Ics]7.5 kA conforming to EN 60898 - 230/400 V AC 50/60 Hz 15 kA conforming to IEC 60947-2 - 230...240 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 - 440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 400...415 V AC 50/60 Hz
Energy limitation class3 conforming to IEC 60947-2
Suitable for isolationYes conforming to IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
C60H4P6AC — Mechanical
ParameterValue
9 mm pitches8
Width72 mm
Height81 mm
Depth73 mm
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Terminal connectionsTunnel type terminals16 mm² flexible Tunnel type terminals25 mm² rigid
Terminal tightening torquePower circuit: 2 N.m upside 2 N.m downside
Comb busbar / distribution block compatibilityNO
Local signalling / indicationON/OFF indication
Contact position indicatorYes
C60H4P6AC — Environmental
ParameterValue
Operating temperature range-25...60 °C
Storage temperature range-40...70 °C
Relative humidity95 % at 55 °C
C60H4P6AC — Approvals
ParameterValue
Standards / complianceEN 60898 IEC 60947-2

Product details

C60H4P6AC — 6 A C-Curve MCB for Distribution Boards

The Schneider Electric C60H4P6AC is a 4-pole miniature circuit breaker from the Multi9 C60H series, rated 6 A at 30 °C with a C trip curve (magnetic tripping between 5 and 10 times In). Rated breaking capacity is 10 kA Icn at 230/400 V AC per EN 60898, with higher Icu values under IEC 60947-2: 15 kA at 400–415 V AC, 30 kA at 230–240 V AC, and up to 50 kA at 250 V DC for the 4P configuration. The thermal-magnetic trip unit combines a bimetal strip for overload protection and a solenoid for short-circuit response. The C curve (5–10× In) is the default for general-purpose loads like lighting, socket outlets, and small motor circuits where inrush is moderate.

Fixed mounting mode, toggle control, and ON/OFF visual indication on the front face. Dimensions are 81 mm high, 72 mm wide, 73 mm deep, occupying 8 modules of 9 mm pitch.

Dual-rated to EN 60898 (domestic-type MCB) and IEC 60947-2 (industrial-type circuit breaker). This dual certification means it qualifies for both household distribution boards (where EN 60898 is required) and industrial control panels (where IEC 60947-2 is the governing standard) — one part number covers both applications. Maximum operating altitude 2000 m. Service breaking capacity (Ics) is 7.5 kA at 230/400 V AC per EN 60898 — meaning after clearing a fault at that level, the breaker remains functional and can be reclosed. Under IEC 60947-2, Ics reaches 15 kA at 230–240 V AC.

Frequently asked questions

What is the breaking capacity of C60H4P6AC?

The C60H4P6AC has a breaking capacity of 10 kA Icn at 230/400 V AC per EN 60898. Under IEC 60947-2, the ultimate breaking capacity (Icu) reaches 15 kA at 400–415 V AC and 30 kA at 230–240 V AC.

What compliance documentation does Schneider provide for C60H4P6AC?

The C60H4P6AC is certified to EN 60898 and IEC 60947-2. It carries tropicalisation class 2 per IEC 60068-1. RoHS and REACH compliance documentation is available from Schneider Electric on request.

MPN
C60H4P6AC