Schneider Electric C60HB210 — 2-Pole MCB (DIN Rail)

C60HB210 Miniature Circuit Breaker, 10A B-Curve 2P, Obsolete

MPNC60HB210
Obsolete

Schneider Electric Multi9 C60H series, C60HB210, miniature circuit breaker, 2-pole, 10 A, B-curve, thermal-magnetic trip.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C60HB210 — Identification
ParameterValue
Product nameC60
Series / familyMulti9
Device short nameC60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution
C60HB210 — Electrical
ParameterValue
Rated current [In]10 A
Number of protected poles2
Pole configuration2P
C60HB210 — Protection
ParameterValue
Tripping curve codeB
Breaking capacity (Icu)10 kA Icn at 230/400 V AC 50/60 Hz conforming to EN 60898 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2 50 kA Icu at 250 V DC 4P conforming to IEC 60947-2
Trip unit technologyThermal-magnetic

Product details

The C60HB210 is a 2-pole miniature circuit breaker from Schneider Electric's Multi9 C60H range, rated at 10 A with a B-curve trip characteristic for distribution applications. The thermal-magnetic trip unit protects wiring and loads against overloads and short circuits, with the B-curve (3-5 In) suited to resistive or general-purpose circuits where inrush is low.

This breaker carries multiple interrupting ratings depending on the standard and voltage. At 230/400 V AC it is rated 10 kA Icn per EN 60898, the standard for household and similar installations. Under IEC 60947-2 (industrial application), the Icu ratings climb: 15 kA at 400-415 V AC, 30 kA at 230-240 V AC, and up to 50 kA at 250 V DC in 4-pole configuration. For a 2-pole unit at 125 V DC, the Icu is 25 kA.

The 2-pole form factor occupies two 18 mm module spaces. Wire termination accepts up to 25 mm² conductor, typical for branch circuit protection in commercial or light industrial panels.

Frequently asked questions

What is the breaking capacity of C60HB210?

The C60HB210 has a 10 kA Icn rating at 230/400 V AC per EN 60898, and IEC 60947-2 Icu ratings of 15 kA at 400-415 V AC, 30 kA at 230-240 V AC, and 25 kA at 125 V DC (2-pole). These cover both residential and industrial fault-level requirements.

What does the B-curve mean on this breaker?

The B-curve trips between 3 and 5 times the rated current (In). For this 10 A breaker, that means magnetic trip occurs between 30 A and 50 A. It is designed for resistive loads and general-purpose circuits where inrush current is minimal, such as lighting or socket outlets.

Where can I buy the C60HB210?

We supply the C60HB210 on a quoted-to-order basis. Since it is obsolete, availability is confirmed at quote time through our independent sourcing network. Request a quote for current pricing and lead time.