Schneider Electric C60HB416 — 2-Pole MCB (DIN Rail)

Schneider Electric C60HB416 C60H MCB, 4P, 16A, Curve B, 10kA

MPNC60HB416
Obsolete

Schneider Electric Multi9 C60H, C60HB416, 4-pole miniature circuit breaker, 16 A, B-curve, 10 kA breaking capacity per EN 60898.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C60HB416 — Identification
ParameterValue
Product nameC60
Series / familyMulti9
Device short nameC60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution
C60HB416 — Electrical
ParameterValue
Rated current [In]16 A
Number of protected poles4
Pole configuration4P
C60HB416 — Protection
ParameterValue
Tripping curve codeB
Breaking capacity (Icu)10 kA Icn at 230/400 V AC 50/60 Hz conforming to EN 60898 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2 50 kA Icu at 250 V DC 4P conforming to IEC 60947-2
Trip unit technologyThermal-magnetic

Product details

The Schneider Electric C60HB416 is a 4-pole miniature circuit breaker from the Multi9 C60H range, rated 16 A with a B tripping curve.

The C60HB416 carries a 10 kA Icn breaking capacity at 230/400 V AC per EN 60898, which is the standard for household and similar installations. Under IEC 60947-2 (industrial), the Icu ratings step up: 10 kA at 440 V AC, 15 kA at 400–415 V AC, 25 kA at 125 V DC (2-pole series), 30 kA at 230–240 V AC, 40 kA at 125 V DC (3-pole), and 50 kA at 250 V DC (4-pole).

The C60HB416 is a DIN-rail mount miniature circuit breaker, 4-pole wide (72 mm at 18 mm per pole). For a field-service swap, the wiring pattern is straightforward — line in at the top, load out at the bottom, with the fourth pole protecting the neutral if the system is wired for 4-pole isolation. The B-curve means it will hold through normal equipment inrush but trip quickly on a hard fault, which simplifies coordination with downstream MCBs in a radial distribution scheme.

Frequently asked questions

Who supplies C60HB416 and how is it quoted for volume purchases?

The C60HB416 is supplied through independent industrial-automation distributors. It is quoted to order against an RFQ — availability and current pricing are confirmed at the time of the quote. No stock or price figures are published for this obsolete part.

What is C60HB416's breaking capacity at 400 V?

The C60HB416 has a 10 kA Icn breaking capacity at 230/400 V AC conforming to EN 60898, and a 15 kA Icu at 400–415 V AC conforming to IEC 60947-2.

What does the B-curve on C60HB416 mean?

The B-curve trips between 3 and 5 times the rated current (48–80 A for this 16 A breaker). It is suited for resistive and general-purpose loads where inrush currents are low, providing faster fault clearance than a C-curve.

What compliance documentation does Schneider provide for C60HB416?

The C60HB416 is certified to EN 60898 for household installations and IEC 60947-2 for industrial applications. Specific RoHS, REACH, and UL documentation should be verified at the time of order, as the part is obsolete and manufacturer documentation may be archived.

MPN