Schneider Electric C60HC163 — 1-Pole MCB (DIN Rail)

C60HC163 Multi9 C60H MCB 1P 63A C-Curve, 30kA

MPNC60HC163
Obsolete

Schneider Electric Multi9 C60H series, C60HC163, 1P 63A C-curve miniature circuit breaker, thermal-magnetic trip, 30 kA Icu at 130 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C60HC163 — Identification
ParameterValue
Product nameC60
Product / component typeMiniature circuit-breaker
Product rangeMulti9
Device short nameC60H
Poles description1P
Number of protected poles1
Device applicationDistribution
C60HC163 — Electrical & Protection
ParameterValue
Rated current (In)63 A
Tripping curve codeC
Breaking capacity (Icu / AIR)30 kA Icu at 130 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 230...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 60 V DC 1P conforming to EN/IEC 60947-2 4 kA Icu at 400...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
Trip unit technologyThermal-magnetic

Product details

The Schneider Electric C60HC163 is a 1-pole C60H miniature circuit breaker from the Multi9 range, rated 63 A with a C-curve thermal-magnetic trip characteristic. It protects a single pole in distribution applications, interrupting faults up to 30 kA Icu at 130 V AC (EN/IEC 60947-2), 15 kA at 230–240 V AC, 20 kA at 60 V DC, and 4 kA at 400–415 V AC.

At 230–240 V AC the rating drops to 15 kA, and at 400–415 V AC to 4 kA. The 20 kA at 60 V DC (1P) covers DC control circuits. These ratings conform to EN/IEC 60947-2, which certifies the breaker for industrial panel use where SCCR headroom matters. For a 63 A single-pole breaker on a 230 V distribution board, the 15 kA Icu is the figure that governs selectivity coordination with the upstream device.

Snap-on DIN-rail mount for standard 35 mm rail in distribution panels or enclosure sub-boards. Single-pole form factor leaves room for adjacent breakers in a multi-pole assembly. The thermal-magnetic trip unit is non-interchangeable — the 63 A rating is fixed at the factory.

Frequently asked questions

What is the breaking capacity of C60HC163 at different voltages?

The C60HC163 is rated 30 kA Icu at 130 V AC, 15 kA at 230–240 V AC, 20 kA at 60 V DC (1P), and 4 kA at 400–415 V AC, all conforming to EN/IEC 60947-2.

What does the C-curve on C60HC163 mean?

The C-curve means the breaker trips between 5 and 10 times its 63 A rated current. It is designed for mixed resistive and moderate inductive loads where inrush current is present but not severe.

Where can I buy C60HC163?

The C60HC163 is sourced to order through our independent distribution network. Submit an RFQ for current availability and pricing — we confirm both at quote time.

What compliance documentation is available for C60HC163?

The breaker carries CE marking and conforms to EN/IEC 60947-2. RoHS and REACH compliance documentation is provided with each lot sourced through our channel.

MPN