Skip to main content
Schneider Electric C60HC202 — 2-Pole MCB (DIN Rail)

C60HC202 C60H MCB 2P 2A Curve C, 10 kA Icu at 440 V

MPNC60HC202
Obsolete

Schneider Electric Multi9 C60H series, C60HC202 miniature circuit breaker, 2-pole, 2 A, curve C, 10 kA Icu at 440 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C60HC202 — Identification
ParameterValue
Product nameC60
Series / familyMulti9
Device short nameC60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution
C60HC202 — Electrical
ParameterValue
Rated current [In]2 A
Number of protected poles2
Pole configuration2P
C60HC202 — Protection
ParameterValue
Tripping curve codeC
Breaking capacity (Icu)10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10000 A Icn at 230/400 V AC 50/60 Hz conforming to EN 60898 25 kA Icu at 125 V DC 2P conforming to EN/IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to EN/IEC 60947-2 50 kA Icu at <= 250 V DC 4P conforming to EN/IEC 60947-2
Trip unit technologyThermal-magnetic

Product details

The C60HC202 is a 2-pole C60H miniature circuit breaker from Schneider Electric's Multi9 range, rated at 2 A with a C trip curve and thermal-magnetic trip technology.

Breaking capacity across standards

This breaker carries a 10 kA Icu at 440 V AC (EN/IEC 60947-2), rising to 15 kA Icu at 400–415 V AC, and 30 kA Icu at 230–240 V AC under the same standard. For residential-grade EN 60898 duty, it is rated 10 kA Icn at 230/400 V AC. On DC circuits, it handles 25 kA Icu at 125 V DC in 2-pole configuration, up to 50 kA Icu at ≤250 V DC in 4-pole.

As a DIN-rail mounted Multi9 MCB, it snaps into the standard 18 mm per-pole footprint in a distribution board or sub-panel. Two protected poles mean it switches both phase and neutral on a single-phase circuit, or two phases on a split-phase or two-phase system. The 2 A rating and C curve make it a typical choice for protecting a 2 A lighting circuit, a small control transformer primary, or a PLC power supply input where the inrush is moderate and the sustained load stays under 2 A.

Frequently asked questions

Where can I buy C60HC202 and how do I get a price?

The C60HC202 is available through our independent distribution network on a quoted-to-order basis. Submit an RFQ for current availability and pricing — figures are confirmed at quote time, not listed here.

What is the closest alternative to C60HC202?

No official successor order code is recorded for the C60HC202. A modern replacement would need to match the 2-pole, 2 A, C-curve, and 10 kA breaking capacity at 440 V AC — typically from the manufacturer's current Acti9 or Easy9 range, but verify footprint and busbar compatibility before substituting.

What is C60HC202's listed range and curve code?

It belongs to the Multi9 range (product name C60) and uses a C trip curve, meaning it trips between 5 and 10 times the 2 A rated current.

What compliance documentation does Schneider provide for C60HC202?

The breaker is rated to EN/IEC 60947-2 for industrial use and EN 60898 for residential use. Specific RoHS/REACH declarations are available through Schneider Electric's product documentation portal for this order code.

MPN