Schneider Electric C6336M500 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric C6336M500 MicroLogic 6.3 E-M Trip Unit, 5

MPNC6336M500
Active

Schneider Electric ComPacT NSX400...630 series, MicroLogic 6.3 E-M electronic trip unit, 500 A at 65 °C, 3-pole, LSIG protection, LCD display, EN/IEC 60947-2.

$460.61 – $1,311.49Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

C6336M500 — Residual Current Protection
ParameterValue
Trip unit technologyElectronic
Local signalling / indicationFlashing LED (green) for ready to operate LED 95 % Ith (red) for temperature over set point
C6336M500 — Electrical Ratings
ParameterValue
Rated operational voltage (Ue)690 V AC 50/60 Hz
Poles description3P
Network typeAC
Network frequency50/60 Hz
C6336M500 — Identification
ParameterValue
Product / component typeTrip unit
Product range / familyComPacT
C6336M500 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-1
C6336M500 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The Schneider Electric C6336M500 is a MicroLogic 6.3 E-M electronic trip unit for the ComPacT NSX400...630 range, rated 500 A at 65 °C. The 500 A rating at 65 °C means this trip unit is calibrated for continuous motor load at that current without derating at the elevated panel temperature; if your enclosure runs hotter, the ambient operating range extends to 70 °C, but you should verify the thermal curve against the motor's full-load amps. The LSIG scheme gives you adjustable long-time pickup from 250 to 500 A (Ir), short-time pickup adjustable across 9 settings from 5 to 13 x Ir, and ground-fault pickup also adjustable — so you can shape the curve to match motor inrush and coordination requirements. The trip unit is 3-pole (3P) with 3D protected poles, meaning all three poles are monitored and protected. The motor tripping classes available are 5, 10, 20, and 30, selectable via the trip unit settings, letting you match the overload curve to the motor's thermal withstand characteristics.

Integration into the ComPacT NSX400...630 frame

This trip unit mounts into a fixed-mount ComPacT NSX400...630 circuit breaker frame. The LCD display provides local readout of energy metering, protection settings, time-stamped events, demand values, and maintenance indicators. The communication capabilities include energy metering data, protection and alarm settings, time-stamped histories and event tables, instantaneous and demand values, maintenance indicators, demand current and power, power quality, and maximeters/minimeters — all accessible via the trip unit's communication port without additional modules. Zone selective interlocking (ZSI) is supported, which allows multiple downstream breakers to communicate trip signals for faster fault clearing while maintaining selectivity — useful in a motor control center with multiple feeders. Class II electrical shock protection means double insulation is provided, so no protective earth connection is required on the trip unit itself.

Frequently asked questions

What is C6336M500's listed range and standards?

It belongs to the ComPacT NSX400...630 range and complies with EN/IEC 60947-2 for low-voltage switchgear and controlgear.

What protection functions does the MicroLogic 6.3 E-M provide?

It provides LSIG protection: long-time (L) overload, short-time (S) short-circuit with fixed delay, instantaneous (I) short-circuit, and ground-fault (G) protection. The long-time pickup is adjustable from 250 to 500 A, short-time pickup adjustable across 9 settings from 5 to 13 x Ir, and ground-fault pickup also adjustable.

What motor protection features does this trip unit include?

Beyond the LSIG curve, it offers complementary motor protection: current unbalance, protracted starting time, stalled rotor, and underload. Motor tripping classes 5, 10, 20, and 30 are selectable.

How do I get current pricing and availability for C6336M500?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote.

What compliance documentation is available for C6336M500?

The trip unit is certified to EN/IEC 60947-2 and carries IP40 protection per IEC 60529. Pollution degree 3 per IEC 60947-1 and Class II electrical shock protection are specified. Specific RoHS, REACH, or UL documentation should be requested at quote time.