Skip to main content
Schneider Electric C6337E570

Schneider Electric C6337E570 MicroLogic 7.3 E Trip Unit, 570

MPN C6337E570
Active

Schneider Electric ComPacT NSX series, MicroLogic 7.3 E electronic trip unit, 570 A at 40 °C, 3P, LSIR protection with integrated earth-leakage, EN/IEC 60947-2.

$22.63 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C6337E570 specifications
ParameterValue
Display typeLCD display
Trip unit typeElectronic
Main product or component typeTrip unit
Voltage440 V AC 50/60 Hz
IP ratingIP40
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
ApplicationDistribution
Operating temperature-25...70 °C

Product details

MicroLogic 7.3 E — 570 A electronic trip unit for ComPacT NSX

The Schneider Electric C6337E570 is the MicroLogic 7.3 E electronic trip unit for the ComPacT NSX400...630 molded-case circuit breaker platform. It's rated 570 A at 40 °C and provides LSIR protection — long-time, short-time, instantaneous, and residual (earth-leakage) — all in one programmable package. The trip unit mounts into the fixed ComPacT NSX breaker frame and communicates energy metering, power quality data, and event logs through the integrated LCD display. Built to EN/IEC 60947-2, this is a Class II, pollution degree 3 device suitable for distribution panels and industrial switchboards. The 3-pole, 3D protected design covers all three phases plus neutral for earth-leakage sensing. The 20-minute thermal memory before and after tripping means the trip curve accounts for prior heating — critical for motor and transformer feeders where cumulative thermal stress matters.

Protection and adjustment ranges

The long-time pickup (Ir) adjusts from 250 to 570 A, with delay (Tr) settable 15...400 s at 1.5 x Ir, 0.35...11 s at 7.2 x Ir, or 0.5...16 s at 6 x Ir. Short-time pickup (Isd) spans 1.5 to 10 x Ir, delay (tsd) 0...0.4 s with I²t on or off. Instantaneous pickup (Ii) adjusts 1.5 to 11 x In. The earth-leakage protection is Class A, integrated, and can be disabled via the IΔn rotary switch. The trip unit operates from -25 to 70 °C and stores from -40 to 85 °C. IP40 front protection keeps dust and incidental contact out of the display and settings interface.

MPN