Schneider Electric C6347A570 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric C6347A570 ComPacT NSX MicroLogic 7.3 E AL

MPNC6347A570
Active

Schneider Electric ComPacT NSX400...630, MicroLogic 7.3 E AL trip unit, 570 A, 4P, electronic LSI protection, LCD display, EN/IEC 60947-2.

$24.40Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

C6347A570 — Residual Current Protection
ParameterValue
Earth-leakage protection class / typeClass A
Trip unit technologyElectronic
Local signalling / indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C6347A570 — Electrical Ratings
ParameterValue
Rated operational voltage (Ue)440 V AC 50/60 Hz
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
C6347A570 — Identification
ParameterValue
Product / component typeTrip unit
Product range / familyComPacT
C6347A570 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-1
C6347A570 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The Schneider Electric C6347A570 is a MicroLogic 7.3 E AL electronic trip unit for the ComPacT NSX400...630 molded-case circuit breaker family. It's rated 570 A at 40 °C, 4-pole, and built for distribution duty on 50/60 Hz AC networks up to 440 V. The EN/IEC 60947-2 listing means it's certified for low-voltage switchgear and controlgear — the standard that governs MCCB coordination and short-circuit performance.

Protection and metering in one package

This unit packs LSI protection — long-time (L) overload, short-time (S) short-circuit, and instantaneous (I) short-circuit — plus integrated earth-leakage protection (Class A). The LCD display gives you energy metering, demand values, time-stamped event logs, and test reports.

Adjustable settings for selectivity

Long-time pickup (Ir) adjusts from 250 to 570 A; long-time delay (tr) is adjustable from 15 to 400 s at 1.5 x Ir. Short-time pickup (Isd) and delay (tsd) are also adjustable — tsd ranges 0 to 0.4 s with I²t on or off. Instantaneous pickup (Ii) is adjustable. Neutral protection can be set to 0.5 x Ir, 1 x Ir, or none, covering 3D + N/2, 4D, or 3D configurations.

Frequently asked questions

What are the key ratings for the C6347A570?

It's a 570 A trip unit at 40 °C, 4-pole, rated operational voltage 440 V AC, with LSI protection and integrated earth-leakage (Class A).

Where can I buy the C6347A570 and get a price?

This part is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote.

What standards does the C6347A570 comply with?

It complies with EN/IEC 60947-2, the standard for low-voltage switchgear and controlgear. Pollution degree 3 per IEC 60947-1, IP40 per IEC 60529, and electrical shock protection Class II.

MPN
C6347A570