Skip to main content
Schneider Electric C63F34V570

Schneider Electric C63F34V570 ComPacT NSX, 570 A, 40 kA, Ear

MPN C63F34V570
Active

Schneider Electric ComPacT NSX, earth leakage circuit breaker, 570 A, 40 kA Icu at 240 V AC, 3P, MicroLogic 4.3 electronic trip unit, EN/IEC 60947-2.

$5,167.80 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C63F34V570 key specifications
ParameterValue
Control typeToggle
Trip unit typeElectronic
Main product or component typeEarth leakage circuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz
IP ratingIP40
Terminal pitch45 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C

All specifications

C63F34V570 additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth110 mm
Width140 mm
Height255 mm
Electrical life cycles8000 cycles at 440 V In/2 4000 cycles at 440 V In 6000 cycles at 690 V In/2 2000 cycles at 690 V In
Mechanical life cycles15000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric C63F34V570 is a ComPacT NSX earth leakage circuit breaker rated at 570 A at 40 °C, with a MicroLogic 4.3 electronic trip unit that combines overload (L), short-time (So), instantaneous (I), and integrated earth-leakage (R) protection in one package. It's a 3-pole unit built for distribution duty, not motor starting — Category A utilization, so it's meant for cable and busbar protection, not switching loads under heavy inrush. The 40 kA Icu at 240 V AC (36 kA at 415 V, 30 kA at 440 V) gives you real fault-current headroom in a panel fed from a transformer or a genset — enough to coordinate downstream without blowing the main. The electronic trip has a 20-minute thermal memory, so after a trip it remembers the heat buildup and won't let you re-close into a still-hot cable.

This breaker bolts to a backplate — no DIN-rail clip. Mount it flat on the back, horizontal or vertical, with front connections on both the line and load sides. At 255 mm tall, 140 mm wide, 110 mm deep, it's a compact frame for 570 A — the NSX630F footprint fits in a standard 600 mm wide switchboard section without crowding the cable ducts.

MPN
C63F34V570