Skip to main content
Schneider Electric C63F34V570 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric C63F34V570 ComPacT NSX, 570 A, 40 kA, Ear

MPNC63F34V570
Active

Schneider Electric ComPacT NSX, earth leakage circuit breaker, 570 A, 40 kA Icu at 240 V AC, 3P, MicroLogic 4.3 electronic trip unit, EN/IEC 60947-2.

$5,167.80Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C63F34V570 — Residual Current Protection
ParameterValue
Earth-leakage protection class / typeClass A
Trip unit technologyElectronic
Local signalling / indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C63F34V570 — Electrical Ratings
ParameterValue
Rated current (In)570 A at 40 °C
Rated operational voltage (Ue)440 V AC 50/60 Hz
Poles description3P
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Overvoltage categoryIV
Electrical durability8000 cycles at 440 V In/2 4000 cycles at 440 V In 6000 cycles at 690 V In/2 2000 cycles at 690 V In
Mechanical durability (operating cycles)15000 cycles
C63F34V570 — Identification
ParameterValue
Product nameComPacT NSX
Product / component typeEarth leakage circuit breaker
Product range / familyComPacT
Device short nameNSX630F
C63F34V570 — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical Flat on the back
Control typeToggle
C63F34V570 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
Operating altitude0...2000 m without derating 2000 m...5000 m with derating
C63F34V570 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The Schneider Electric C63F34V570 is a ComPacT NSX earth leakage circuit breaker rated at 570 A at 40 °C, with a MicroLogic 4.3 electronic trip unit that combines overload (L), short-time (So), instantaneous (I), and integrated earth-leakage (R) protection in one package. It's a 3-pole unit built for distribution duty, not motor starting — Category A utilization, so it's meant for cable and busbar protection, not switching loads under heavy inrush. The 40 kA Icu at 240 V AC (36 kA at 415 V, 30 kA at 440 V) gives you real fault-current headroom in a panel fed from a transformer or a genset — enough to coordinate downstream without blowing the main. The electronic trip has a 20-minute thermal memory, so after a trip it remembers the heat buildup and won't let you re-close into a still-hot cable.

This breaker bolts to a backplate — no DIN-rail clip. Mount it flat on the back, horizontal or vertical, with front connections on both the line and load sides. At 255 mm tall, 140 mm wide, 110 mm deep, it's a compact frame for 570 A — the NSX630F footprint fits in a standard 600 mm wide switchboard section without crowding the cable ducts.

Frequently asked questions

What are the key ratings for the C63F34V570?

Rated 570 A at 40 °C, with a breaking capacity of 40 kA Icu at 240 V AC (36 kA at 415 V, 30 kA at 440 V) per IEC 60947-2. It uses a MicroLogic 4.3 electronic trip unit with L, So, I, and integrated earth-leakage protection.

What compliance standards does the C63F34V570 meet?

It complies with EN/IEC 60947-2 and carries pollution degree 3 per IEC 60664-1, overvoltage category IV, and IK07 impact resistance per IEC 62262.

How do I get pricing and availability for the C63F34V570?

Submit an RFQ through this listing; availability and current pricing are confirmed at quote time through our independent distribution network.

MPN
C63F34V570