Skip to main content
Schneider Electric C63V36M500 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric C63V36M500 ComPacT NSX 500 A, 85 kA ICu,

MPNC63V36M500
Active

Schneider Electric ComPacT NSX, C63V36M500, 3P 500 A MCCB with MicroLogic 6.3 E-M electronic trip unit, 85 kA Icu at 500 V AC, motor protection, EN/IEC 60947-2.

$19.85Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C63V36M500 — Residual Current Protection
ParameterValue
Trip unit technologyElectronic
Local signalling / indicationFlashing LED (green) for ready to operate LED 95 % Ith (red) for temperature over set point
C63V36M500 — Electrical Ratings
ParameterValue
Rated current (In)500 A at 65 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz
Poles description3P
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Overvoltage categoryIII
Electrical durability8000 cycles at 440 V In/2 4000 cycles at 440 V In 6000 cycles at 690 V In/2 2000 cycles at 690 V In
Mechanical durability (operating cycles)15000 cycles
C63V36M500 — Identification
ParameterValue
Product nameComPacT NSX
Product / component typeCircuit breaker
Product range / familyComPacT
Device short nameNSX630HB1
C63V36M500 — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical Flat on the back
Control typeToggle
C63V36M500 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
Operating altitude0...2000 m without derating 2000 m...5000 m with derating
C63V36M500 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The Schneider Electric C63V36M500 is a ComPacT NSX630HB1 molded-case circuit breaker with a MicroLogic 6.3 E-M electronic trip unit, rated 500 A at 65 °C. It's built for motor-protection duty (device application: motor protection) and carries a 85 kA Icu breaking capacity at 500 V AC 50/60 Hz per EN/IEC 60947-2. The 3-pole unit (3P) uses a toggle control and an LCD display for local signalling — a flashing green LED for ready status, a red LED at 95 % Ith for overtemperature. The electronic trip unit provides L (long-time overload), So (short-time short-circuit), I (instantaneous), and G (ground-fault) protection, with motor tripping classes 5, 10, 20, and 30 selectable.

At 690 V AC the Icu drops to 75 kA, still substantial for industrial feeders. Mechanical durability is 15000 cycles. That's enough for a motor-starting application where the breaker operates infrequently (a few cycles per day), not for a switching duty that cycles hourly.

Upside and downside connections are front-facing, so it panels into a dead-front switchboard without rear access. Connection pitch is 45 mm. Overvoltage category III suits it for fixed-installation distribution panels. Operating altitude is 0-2000 m without derating, 2000-5000 m with derating.

Frequently asked questions

What is the breaking capacity of C63V36M500?

85 kA Icu at 500 V AC 50/60 Hz per IEC 60947-2, 80 kA at 525 V, and 75 kA at 660/690 V.

What trip unit does C63V36M500 use?

It uses a MicroLogic 6.3 E-M electronic trip unit, providing L (long-time overload), So (short-time short-circuit), I (instantaneous), and G (ground-fault) protection, with motor tripping classes 5, 10, 20, and 30.

MPN
C63V36M500