Skip to main content
Schneider Electric CAD32FL — Contactors

Schneider TeSys CAD32FL Control Relay, 3NO+2NC, 110 VDC Coil

MPNCAD32FL
Obsolete

Schneider Electric TeSys D control relay CAD32FL, 3 NO + 2 NC, ≤690 V, 110 V DC low consumption coil, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

CAD32FL — Identification
ParameterValue
Product / component typeControl relay
Series / rangeTeSys
ApplicationControl circuit
CAD32FL — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)10 MOhm
Utilisation categoryAC-15 DC-13 AC-14
CAD32FL — Environmental
ParameterValue
IP degree of protectionIP2X conforming to VDE 0106
Operating altitude0...3000 m
Mechanical robustnessShocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTH conforming to IEC 60068
CAD32FL — Approvals
ParameterValue
StandardsEN/IEC 60947-5-1 GB/T 14048.5 UL 60947-5-1 CSA C22.2 No 60947-5-1 JIS C8201-5-1
CAD32FL — Mechanical
ParameterValue
Width45 mm
Height77 mm
Depth93 mm
CAD32FL — Other specifications
ParameterValue
Device short nameCAD
Pole contact composition3 NO + 2 NC
Ambient air temperature for storage-60...80 °C
Ambient air temperature for operation-40...60 °C 60...70 °C with derating

Product details

The CAD32FL is a TeSys D control relay from Schneider Electric, configured with 3 normally-open and 2 normally-closed pole contacts. It is designed for control-circuit switching in industrial panels, rated for operational voltages up to 690 V and fitted with a 110 V DC low-consumption coil. Its utilisation categories cover AC-15 (solenoid valve and electromagnetic clutch loads), AC-14 (small motor loads up to 72 VA), and DC-13 (solenoid and electromagnetic brake loads), making it suitable for a range of control-circuit applications in motor starters and general automation panels. The relay carries approvals under EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, and JIS C8201-5-1, so it meets the certification requirements for panels destined for North American, European, and Japanese markets.

The 3 NO + 2 NC contact arrangement gives you three independent make circuits and two break circuits in a single relay package — enough to control a contactor coil, a pilot light, and a PLC input while keeping a separate NC feedback path for status monitoring. Rated for operation from -40 to 60 °C without derating, and up to 70 °C with derating applied. The storage range of -60 to 80 °C covers most shipping and warehouse conditions. The 0 to 3000 m altitude rating means it works at typical plant elevations without performance adjustment. Mechanical robustness is specified for shock and vibration: the relay withstands 10 Gn shocks (11 ms) when open, 15 Gn when closed, and vibration at 2 Gn (open) or 4 Gn (closed) across 5–300 Hz. This is relevant for panels mounted on machinery or in mobile equipment where the relay must hold its state under vibration. The TH protective treatment per IEC 60068 indicates the relay is treated against tropical humidity and condensation, which is useful for panels in non-conditioned environments or coastal plants.

Frequently asked questions

What are the key ratings of the CAD32FL?

It is a control relay with 3 NO + 2 NC contacts, rated for operational voltages up to 690 V, with a 110 V DC low consumption coil. It covers utilisation categories AC-15, AC-14, and DC-13, and operates from -40 to 60 °C (up to 70 °C with derating) at altitudes up to 3000 m.

What certifications does the CAD32FL carry?

It is certified to EN/IEC 60947-5-1, GB/T 14048.5, UL 60947-5-1, CSA C22.2 No 60947-5-1, and JIS C8201-5-1, covering European, Chinese, North American, and Japanese regulatory requirements.

How do I source the CAD32FL given it is obsolete?

Since it is obsolete, sourcing is through the surplus and broker market. Submit an RFQ for current availability and pricing — we can quote to order against your request.

MPN
CAD32FL