CAD506KD — Identification
ParameterValue
Product / component typeControl relay
Product rangeTeSys TeSys Deca
CAD506KD — Electrical
ParameterValue
Rated operational voltage (Ue)10 MOhm
Pole / contact composition5 NO
CAD506KD — Mechanical
ParameterValue
Width45 mm
Height77 mm
Depth93 mm
CAD506KD — Environmental
ParameterValue
IP protection ratingIP2X front face conforming to VDE 0106
Operating ambient temperature-40...60 °C 60...70 °C with derating
Storage ambient temperature-60...80 °C
Operating altitude0...3000 m
CAD506KD — Approvals
ParameterValue
Conformance standardsEN/IEC 60947-5-1 GB/T 14048.5 UL 60947-5-1 CSA C22.2 No 60947-5-1 JIS C8201-5-1

Product details

The CAD506KD is a TeSys Deca control relay from Schneider Electric, carrying 5 normally-open contacts rated for control-circuit duty. It switches loads in AC-14, AC-15, and DC-13 utilisation categories — the AC-15 rating (inductive solenoid loads) is the one that governs most panel applications, not the higher AC-14 resistive figure. The 100 VDC standard coil means it pulls in reliably on a 100 VDC control bus; the lugs-ring termination suits permanent wiring in a panel, not quick-disconnect.

The 45 mm wide body clips onto a DIN rail inside an enclosure. Front-face IP2X per VDE 0106 means accidental finger contact with live terminals is blocked — the panel builder can leave the front cover off during commissioning without a shock hazard. Depth of 93 mm and height of 77 mm leave enough room for wiring ducts alongside it on the rail. Operating range is -40 to 60 °C (derated above 60 °C), so it lives in an unheated cabinet without a heater as long as the ambient stays within that band.

Frequently asked questions

What certifications does CAD506KD carry?

It is certified to EN/IEC 60947-5-1, GB/T 14048.5, UL 60947-5-1, CSA C22.2 No 60947-5-1, and JIS C8201-5-1. Protective treatment TH conforms to IEC 60068 for humid environments.

What is the contact configuration and coil voltage?

Five normally-open (5 NO) contacts. The standard coil is 100 VDC. Termination is lugs-ring terminals for permanent wiring.

What utilisation categories does it cover?

AC-14 (resistive/electronic loads), AC-15 (inductive solenoid loads), and DC-13 (DC solenoids/contactors). For motor control circuits, the AC-15 rating is the one that matters most.