Skip to main content
Schneider Electric CAD50AEL

Schneider CAD50AEL TeSys Deca Control Relay, 5NO, 48V DC

MPN CAD50AEL
Active

Schneider Electric TeSys Deca CAD50AEL control relay, 5NO contacts, 48V DC low consumption coil, snap-in terminals, <=690V rated operational voltage.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

CAD50AEL specifications
ParameterValue
Main product or component typeControl relay
Utilization categoryAC-15 AC-14 DC-13
IP ratingIP2X
Temp storage max80 °C
Temp storage min-60 °C
Temp operating max70 °C
Temp operating min-40 °C
Storage temperature-60...80 °C
Depth93 mm
Width45 mm
Height107 mm
ApplicationControl circuit
Operating temperature-40...60 °C 60...70 °C with derating

Product details

It uses a 48V DC low-consumption coil and terminates via snap-in terminals for quick panel wiring. Rated for utilisation categories AC-15, AC-14, and DC-13, this relay handles solenoid and electromagnetic loads typical in control panels — AC-15 covers electromagnetic devices above 72 VA, AC-14 covers those below 72 VA, and DC-13 covers solenoids with a DC coil. The 5NO contact arrangement gives you five independent normally-open switching paths in a single 45 mm wide package. The relay is approved to EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, and JIS C8201-5-1, so it passes inspection for panels shipping to North America, Europe, China, and Japan.

The CAD50AEL measures 45 mm wide by 107 mm high by 93 mm deep — a standard TeSys Deca footprint that clips onto a DIN rail inside the control cabinet. The front face carries IP2X protection per VDE 0106, meaning finger-safe against accidental contact when the panel door is open. Operating temperature spans -40 to 60 °C, with derating allowed up to 70 °C. Storage range is -60 to 80 °C.

For BOM freeze or compliance audits, the relay carries protective treatment TH conforming to IEC 60068 (tropicalisation) and mechanical robustness ratings: shocks of 10 Gn for 11 ms (relay open) and 15 Gn for 11 ms (relay closed), plus vibration resistance of 2 Gn (open) and 4 Gn (closed) across 5-300 Hz per IEC 60068-2-27 and IEC 60068-2-6.

MPN