Skip to main content
Schneider Electric CAD50ASL — Motor Control Accessories

Schneider Electric CAD50ASL TeSys Deca Control Relay, 5NO, 7

MPNCAD50ASL
Active

Schneider Electric TeSys Deca control relay, CAD50ASL, 5NO, <=690V, 72V DC low consumption coil, snap-in terminals.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

CAD50ASL — Identification
ParameterValue
Product / component typeControl relay
Product rangeTeSys
CAD50ASL — Electrical
ParameterValue
Rated operational voltage (Ue)10 MOhm
Pole / contact composition5 NO
CAD50ASL — Mechanical
ParameterValue
Width45 mm
Height107 mm
Depth93 mm
CAD50ASL — Environmental
ParameterValue
IP protection ratingIP2X front face conforming to VDE 0106
Operating ambient temperature-40...60 °C 60...70 °C with derating
Storage ambient temperature-60...80 °C
Operating altitude0...3000 m
CAD50ASL — Approvals
ParameterValue
Conformance standardsEN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 JIS C8201-5-1

Product details

The CAD50ASL is a TeSys Deca control relay from Schneider Electric, built for switching loads in control circuits. It carries five normally open (5 NO) pole contacts and a 72 V DC low-consumption coil, rated for operational voltages up to 690 V. The utilisation categories — AC-15, AC-14, and DC-13 — define its switching capability: AC-15 covers solenoid and electromagnetic loads above 72 VA, AC-14 handles smaller solenoids below 72 VA, and DC-13 applies to electromagnets with parallel diodes. This means the relay is suited for PLC output isolation, contactor coil switching, and general signal-level control in panels where the coil draw stays within the DC-13 curve.

The front face carries an IP2X degree of protection per VDE 0106, meaning it resists finger contact — adequate for enclosed panel mounting but not for exposed or washdown zones. Operating temperature spans -40 to 60 °C, with derating required above 60 °C up to 70 °C; storage range is -60 to 80 °C. Altitude tolerance goes to 3000 m without derating, which covers most control cabinets outside high-altitude installations.

Mechanical robustness for the panel

The relay is rated for shock and vibration per IEC 60068-2-27 and IEC 60068-2-6. It withstands 10 Gn for 11 ms in the open position and 15 Gn for 11 ms closed, with vibration resistance of 2 Gn (5–300 Hz) open and 4 Gn closed. This makes it suitable for mounting on panels near moderate industrial vibration sources like contactors or small motors, though it is not rated for direct machine mounting on high-vibration equipment.

Frequently asked questions

What standards does the CAD50ASL comply with?

It complies with EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, and JIS C8201-5-1, covering control circuit switching devices.

What is the CAD50ASL's contact configuration?

It has five normally open (5 NO) contacts.

What is the operating temperature range for the CAD50ASL?

It operates from -40 to 60 °C, with derating required between 60 and 70 °C.

MPN