Skip to main content
Schneider Electric DOMF01202

Schneider Electric DOMF01202 Domae MCB, 2A C-Curve 2P 6kA

MPN DOMF01202
Active

Schneider Electric Domae MCB, 2A C-curve, 2P, 6kA breaking capacity, 230V AC, clip-on DIN rail, thermal-magnetic trip, white.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

DOMF01202 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage230 V AC 50/60 Hz
Breaking capacityIcn 6000 A
Terminal pitch18 mm between phases
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C
Storage temperature-40...85 °C
ColorWhite

All specifications

DOMF01202 additional specifications
ParameterValue
Depth71.5 mm
Width36 mm
Height81 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationProtection
Operating temperature-5...60 °C

Product details

The Schneider Electric DOMF01202 is a Domae miniature circuit breaker rated 2 A with a C-curve, 2 poles, and a breaking capacity of Icn 6000 A per IEC 60898-1. It clips onto a DIN rail and uses a thermal-magnetic trip unit to protect final circuits in residential or light commercial panels.

What the ratings mean for fit

The C-curve (magnetic trip 5–10 × In) means it handles moderate inrush from small motors or transformers without nuisance tripping — common for general-purpose socket circuits and lighting. At 2 A it protects a low-current branch, e.g. a control transformer or a small pump. The 6 kA breaking capacity at 230 V AC is the maximum fault current it can safely interrupt. In a domestic or light commercial panel where the prospective short-circuit current stays under 6 kA, this breaker clears the fault without upstream damage. The 2-pole version (2P) switches both line and neutral, with neutral on the left. Thermal-magnetic trip technology means the thermal bimetal handles overloads (slow curve), while the solenoid handles short-circuits (instantaneous). The 18 mm connection pitch between phases matches standard busbar comb systems — check compatibility with your distribution block.