Schneider Electric DOMF01216 — 2-Pole MCB (DIN Rail)

Schneider Electric DOMF01216 Domae MCB, 16 A, C Curve, 2P, 6

MPNDOMF01216
Active

Schneider Electric Domae miniature circuit breaker, DOMF01216, 2P, 16 A, C curve, 6000 A breaking capacity, clip-on DIN rail mount, white.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

DOMF01216 — Identification
ParameterValue
Series / familyDomae
Device short nameDomae MCB
Product / component typeMiniature circuit-breaker
Device applicationProtection
DOMF01216 — Electrical
ParameterValue
Rated current [In]16 A
Number of protected poles1
Pole configuration2P
Rated operational voltage [Ue]230 V AC 50/60 Hz
Network type (AC/DC)AC
Network frequency50/60 Hz
DOMF01216 — Protection
ParameterValue
Tripping curve codeC
Magnetic tripping limit5...10 x In
Breaking capacity (Icu)Icn 6000 A
Overvoltage categoryIII
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
DOMF01216 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height81 mm
Depth71.5 mm
Mounting supportDIN rail
Mounting modeClip-on
Terminal connectionsTunnel type terminals (top or bottom) - 1...25 mm² - rigid Tunnel type terminals (top or bottom) - 1...16 mm² - flexible
Terminal tightening torque2 N.m top or bottom
Comb busbar / distribution block compatibilityYES
DOMF01216 — Environmental
ParameterValue
Operating temperature range-5...60 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
DOMF01216 — Approvals
ParameterValue
Standards / complianceIEC 60898-1

Product details

The Schneider Electric DOMF01216 is a Domae miniature circuit breaker (MCB) with a 16 A rated current, C tripping curve, and 2 poles.

The C curve (magnetic tripping limit 5...10 x In) means the breaker tolerates moderate inrush currents — typical for lighting banks, small transformers, and motorized loads — without nuisance tripping. The 6000 A breaking capacity (Icn) is the maximum fault current it can safely interrupt at 230 V AC; that covers most domestic and light commercial service entrances where the prospective short-circuit current stays under 6 kA. The thermal-magnetic trip unit combines a bimetal strip for overload protection and a solenoid for short-circuit response. The 2-pole version (2P) switches both phase and neutral, with the neutral on the left side of the unit. Rated operational voltage is 230 V AC at 50/60 Hz, which is the standard single-phase supply in many regions. The IP20 rating on the body (IP40 in a modular enclosure) means it is protected against solid objects larger than 12 mm but not against water ingress — suitable for indoor distribution boards only.

The 36 mm width (4 x 9 mm pitches) occupies two standard module spaces. Tunnel-type terminals accept 1...25 mm² rigid or 1...16 mm² flexible cable; tighten to 2 N·m. The 18 mm connection pitch between phases is standard for comb busbar systems — the unit is listed as compatible with comb busbars and distribution blocks.

Frequently asked questions

Where can I buy DOMF01216 and how do I get a price?

The DOMF01216 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is DOMF01216's listed depth?

The depth is 71.5 mm.

What compliance documentation does this brand provide for DOMF01216?

The part carries CE marking and is designed to IEC 60898-1. It also meets tropicalisation class 2 per IEC 60068-1.

MPN
DOMF01216