Skip to main content
Schneider Electric DOMF01316 — Circuit Breaker Accessories

Schneider Electric DOMF01316 Domae MCB, 3P, 16 A, C Curve, 6

MPNDOMF01316
Active

Schneider Electric Domae miniature circuit breaker, DOMF01316, 3-pole, 16 A, C curve, 6000 A breaking capacity, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

DOMF01316 — Identification
ParameterValue
Product / component typeMiniature circuit-breaker
Product rangeDomae
Device applicationProtection
DOMF01316 — Electrical
ParameterValue
Network type (AC/DC)AC
Rated current [In]16 A
Rated operational voltage [Ue]400 V AC 50/60 Hz
Network frequency50/60 Hz
Poles description3P
Magnetic tripping limit5...10 x In
DOMF01316 — Protection & Performance
ParameterValue
Breaking capacityIcn 6000 A
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Mechanical durability20000 cycles
Electrical durability10000 cycles
DOMF01316 — Mechanical
ParameterValue
Connections / terminalsTunnel type terminals (top or bottom) - 1...25 mm² - rigid Tunnel type terminals (top or bottom) - 1...16 mm² - flexible
Connection pitch18 mm between phases
Device short nameDomae MCB
Control typeToggle
Mounting modeClip-on
Mounting supportDIN rail
Usable 9 mm pitches6
Width54 mm
Height81 mm
Depth71.5 mm
ColourWhite
DOMF01316 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Operating ambient air temperature-5...60 °C
Storage ambient air temperature-40...85 °C
DOMF01316 — Approvals
ParameterValue
StandardsIEC 60898-1
DOMF01316 — Specifications
ParameterValue
Curve codeC
Number of protected poles3

Product details

The Schneider Electric DOMF01316 is a Domae miniature circuit breaker, 3-pole, rated 16 A with a C curve and 6000 A breaking capacity per IEC 60898-1. It clips onto DIN rail, occupies 6 x 9 mm pitches (54 mm wide), and protects downstream circuits in residential or light commercial distribution boards.

The 6000 A Icn breaking capacity at 400 V AC covers most domestic and light commercial fault levels; if your installation requires 10 kA or higher, step up to the Domae NG or Acti9 ranges. Rated operational voltage is 400 V AC at 50/60 Hz, so it directly replaces a 3-pole MCB in a three-phase panel.

Panel integration

Clip-on mounting to DIN rail, 54 mm wide (6 x 9 mm pitches). Tunnel terminals accept 1–25 mm² rigid or 1–16 mm² flexible; wire stripping length 14 mm, tightening torque 2 N.m. IP20 finger-safe with the modular enclosure providing IP40. Connection pitch is 18 mm between phases, compatible with standard comb busbars.

Frequently asked questions

Where can I buy DOMF01316?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

What is the breaking capacity of DOMF01316?

Icn 6000 A per IEC 60898-1 at 400 V AC.

What compliance documentation does DOMF01316 carry?

CE marked, conforms to IEC 60898-1 and IEC 60068-1 (tropicalisation class 2).

MPN