Schneider Electric DOMF01340 — Circuit Breaker Accessories

Schneider Electric DOMF01340 Domae MCB, 3P, 40 A, C Curve, 6

MPNDOMF01340
Active

Schneider Electric Domae MCB, 3P, 40 A, C Curve, 6000 A, IEC 60898-1, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

DOMF01340 — Identification
ParameterValue
Product / component typeMiniature circuit-breaker
Product rangeDomae
Device applicationProtection
DOMF01340 — Electrical
ParameterValue
Network type (AC/DC)AC
Rated current [In]40 A
Rated operational voltage [Ue]400 V AC 50/60 Hz
Network frequency50/60 Hz
Poles description3P
Magnetic tripping limit5...10 x In
DOMF01340 — Protection & Performance
ParameterValue
Breaking capacityIcn 6000 A
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Mechanical durability20000 cycles
Electrical durability10000 cycles
DOMF01340 — Mechanical
ParameterValue
Connections / terminalsTunnel type terminals (top or bottom) - 1...35 mm² - rigid Tunnel type terminals (top or bottom) - 1...25 mm² - flexible
Connection pitch18 mm between phases
Device short nameDomae MCB
Control typeToggle
Mounting modeClip-on
Mounting supportDIN rail
Usable 9 mm pitches6
Width54 mm
Height81 mm
Depth71.5 mm
ColourWhite
DOMF01340 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Operating ambient air temperature-5...60 °C
Storage ambient air temperature-40...85 °C
DOMF01340 — Approvals
ParameterValue
StandardsIEC 60898-1
DOMF01340 — Specifications
ParameterValue
Curve codeC
Number of protected poles3

Product details

The DOMF01340 is a 3-pole miniature circuit breaker from Schneider Electric's Domae range, rated 40 A with a C trip curve and 6 kA breaking capacity per IEC 60898-1.

For a 3-phase distribution sub-feed, that's roughly 27 kW of connected load at 400 V line-to-line — enough for a small machine cell or a lighting distribution board. The thermal-magnetic trip unit combines a bimetal strip for overload protection (slow response to sustained overcurrent) and a solenoid for short-circuit protection (instantaneous above the magnetic threshold). The C curve's 5 to 10 x In magnetic trip range means the breaker holds through the inrush of a small motor or a bank of fluorescent ballasts but still clears a hard fault fast enough to protect the downstream cable. The operating temperature range of -5 to 60 °C covers most heated or ventilated enclosures, and the 95 % humidity at 55 °C rating (tropicalisation class 2 per IEC 60068-1) means it won't corrode or track in a humid plant environment. Mechanical durability of 20,000 cycles and electrical durability of 10,000 cycles under rated load are typical for this class of MCB. For a panel that sees daily on-load switching (like a machine disconnect), 10,000 electrical cycles translates to roughly 27 years of one operation per day — not a wear-out concern in most installations.

Integration notes

The breaker occupies 6 module pitches at 9 mm each (54 mm total width) on a DIN rail. The 18 mm phase-to-phase connection pitch matches standard busbar systems for the Domae range, so you can feed all three poles from a single comb busbar without extra jumpers. Tunnel terminals accept up to 35 mm² rigid or 25 mm² flexible cable; strip 14 mm and torque to 3.5 N.m. The toggle actuator gives clear visual indication of the contact position — no ambiguity when you're racking out a panel.

Frequently asked questions

Where can I buy DOMF01340 and how is it quoted?

The DOMF01340 is sourced and quoted to order against an RFQ through independent industrial-automation distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead-time estimate.

What is the breaking capacity of DOMF01340?

The rated breaking capacity (Icn) is 6000 A per IEC 60898-1 at 400 V AC. That is the maximum fault current it can safely interrupt under standard test conditions.

What does the C curve mean on this breaker?

The C curve means the magnetic trip activates at 5 to 10 times the rated current (200 to 400 A for this 40 A unit). It is designed for circuits with moderate inrush — lighting, small motors, general socket outlets — where you need to ride through the start-up surge but still clear a short circuit quickly.

What compliance documentation does Schneider provide for DOMF01340?

The breaker carries CE marking and is designed to IEC 60898-1. It also meets tropicalisation class 2 per IEC 60068-1 for humidity resistance. For specific RoHS or REACH declarations, the manufacturer's documentation should be consulted at the time of order.

MPN
DOMF01340