Schneider Electric ENW13204 — Air Circuit Breakers

Schneider Electric ENW13204 EasyPact NW Circuit Breaker, 125

MPNENW13204
Active

Schneider Electric EasyPact NW, ENW13204, 3-pole drawout circuit breaker, 1250 A at 40 °C, 66 kA Icu at 440 V AC, IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ENW13204 — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact NW
ApplicationDistribution
ENW13204 — Electrical ratings
ParameterValue
Rated current (In)1250 A at 40 °C
Rated operational voltage (Ue)440 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2
ENW13204 — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)55 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)50 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)75 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeC
ENW13204 — Performance
ParameterValue
Breaking time, max.35 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 5000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B
ENW13204 — Mechanical & connection
ParameterValue
Mounting modeDrawout
Mounting supportRail Base plate
Contact position indicatorYes
Width288 mm
Height322 mm
Depth277 mm
Connection pitch70 mm without spreader
Connection locationRear
ENW13204 — Environmental
ParameterValue
Operating ambient temperature-5...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP30
Pollution degree3 conforming to IEC 60664-1
ENW13204 — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

1250 A drawout breaker for distribution — ENW13204

The Schneider Electric ENW13204 is a 3-pole drawout circuit breaker from the EasyPact NW range, rated 1250 A at 40 °C and built to IEC 60947-2 for distribution duty. The 55 kA Ics service breaking capacity (same voltage range) tells you it can reclose after a fault at that level, not just survive one.

Drawout mounting allows the breaker to slide out of its cradle for inspection or swap without disturbing bus connections. The 50 kA Icw short-time withstand for 1 second supports selective coordination. The 5000-cycle electrical durability without maintenance and 10,000 cycles mechanical without maintenance are the numbers a reliability engineer checks for a high-cycle application like a capacitor bank or furnace transformer. With maintenance, mechanical durability stretches to 20,000 cycles.

Frequently asked questions

What is the closest alternative to ENW13204 in the EasyPact NW family?

Within the EasyPact NW range, the closest sibling is the ENW13204 itself — it's the 1250 A, 66 kA, 3-pole drawout variant. A different breaking capacity code or pole count would change the order code; no direct pin-compatible substitute exists with different ratings. For a parametric match, compare the rated current (1250 A at 40 °C) and Icu (66 kA at 440 V AC) against other EasyPact NW breakers.

What is ENW13204's listed depth?

277 mm. Combined with the 322 mm height and 288 mm width, it fits standard switchgear cubicle depths.

MPN