Schneider Electric ENW15511 — Air Circuit Breakers

Schneider Electric ENW15511 EasyPact NW Closing Coil, 110/13

MPNENW15511
Active

Schneider Electric EasyPact NW, XF closing coil, electrically operated, 110/130 V AC/DC 50/60 Hz, 200 VA inrush / 4.5 W holding.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ENW15511 — Identification
ParameterValue
Product typeClosing coil
RangeEasyPact
Product rangeEasyPact NW
ApplicationControl

Mechanical & connection

ENW15511 — Mechanical & connection
ParameterValue
Control typeElectrically operated

Other specifications

ENW15511 — Other specifications
ParameterValue
Response time70 ms at 800 A (EasyPact MVS) 70 ms at 100 A (EasyPact MVS) 70 ms at 1250 A (EasyPact MVS) 70 ms at 1600 A (EasyPact MVS) 70 ms at 2000 A (EasyPact MVS) 70 ms at 2500 A (EasyPact MVS) 70 ms at 3200 A (EasyPact MVS) 70 ms at 4000 A (EasyPact MVS)
Device short nameXF
Control signal typeMaintained
Supply inrush power200 VA 200 ms 200 W 200 ms
Supply holding power4.5 W 4.5 VA
Voltage release typeClosing coil
Threshold tripping voltageRemote control: 0.85...1.1 Un closing
Coil voltage110/130 V AC/DC 50/60 Hz

Product details

Closing coil for EasyPact NW air circuit breakers

The Schneider Electric ENW15511 is a closing coil for the EasyPact NW range of air circuit breakers. It is an electrically operated, maintained-control coil that closes the breaker when its control voltage is applied. Rated for 110/130 V AC/DC at 50/60 Hz, it draws 200 VA (200 W) inrush for 200 ms and settles to 4.5 VA (4.5 W) holding power — the inrush figure matters for sizing the control transformer feeding it.

The 200 VA inrush spike (200 ms) is the key load on the control supply — a transformer or power supply must handle that transient without dropping below the coil's operating threshold of 0.85...1.1 Un. The 4.5 W holding power is negligible once the breaker is closed. The closing coil operates on a maintained signal (voltage present = closed; removed = open), which is standard for remote closing via a pushbutton or PLC output. The 70 ms response time at all current ratings (100 A through 4000 A) means the breaker closes in under a tenth of a second from signal application.

Frequently asked questions

What is the control voltage for ENW15511?

The closing coil is rated 110/130 V AC/DC, 50/60 Hz. It operates on a maintained control signal within 0.85 to 1.1 times the rated voltage.

Where can I buy ENW15511 and get current pricing?

The ENW15511 is available to order through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time.