Skip to main content
Schneider Electric ENW15512 — Air Circuit Breakers

Schneider Electric ENW15512 EasyPact NW Closing Coil, 220/25

MPNENW15512
Active

Schneider Electric EasyPact NW, XF closing coil, electrically operated, 220/250 V AC/DC 50/60 Hz, 200 VA/W inrush, 4.5 VA/W holding.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ENW15512 — Identification
ParameterValue
Product typeClosing coil
RangeEasyPact
Product rangeEasyPact NW
ApplicationControl

Mechanical & connection

ENW15512 — Mechanical & connection
ParameterValue
Control typeElectrically operated

Other specifications

ENW15512 — Other specifications
ParameterValue
Response time70 ms at 800 A (EasyPact MVS) 70 ms at 100 A (EasyPact MVS) 70 ms at 1250 A (EasyPact MVS) 70 ms at 1600 A (EasyPact MVS) 70 ms at 2000 A (EasyPact MVS) 70 ms at 2500 A (EasyPact MVS) 70 ms at 3200 A (EasyPact MVS) 70 ms at 4000 A (EasyPact MVS)
Device short nameXF
Control signal typeMaintained
Supply inrush power200 VA 200 ms 200 W 200 ms
Supply holding power4.5 VA 4.5 W
Voltage release typeClosing coil
Threshold tripping voltageRemote control: 0.85...1.1 Un closing
Coil voltage220/250 V AC/DC 50/60 Hz

Product details

Closing coil for EasyPact NW — what the ratings mean

The ENW15512 is a closing coil in the Schneider Electric EasyPact NW range, device short name XF. It's the electrically operated coil that pulls in the main contacts when you apply control voltage — no manual lever, no motor operator, just a maintained signal to close and hold. Rated 220/250 V AC/DC at 50/60 Hz, so it works on either supply without a separate rectifier or DC-DC converter. That dual-rated control voltage simplifies panel wiring — one coil part number covers both the AC control transformer and the DC battery-backed bus common in switchgear. Inrush power hits 200 VA (or 200 W) for 200 ms to overcome the magnetic gap and spring load. Once the armature seats, holding power drops to 4.5 VA or 4.5 W — about 20 mA at 220 V DC. That low sustained draw keeps the control transformer and DC supply lightly loaded in the closed state. The coil is designed for maintained control signal type — voltage stays on to keep the breaker closed. Threshold tripping voltage is 0.85 to 1.1 Un for reliable closing across the full operating range of the control bus.

Integration into the EasyPact NW frame

This coil mounts into the EasyPact NW breaker's control mechanism — the XF designation indicates the closing coil variant for electrically operated breakers. It replaces or upgrades the existing closing coil in the NW frame without modifying the breaker's main pole assembly or arc chamber. Response time is 70 ms across the entire EasyPact MVS current range (100 A through 4000 A), which means the coil's mechanical stroke and magnetic circuit are consistent regardless of the breaker frame size. That 70 ms closing time factors into coordination studies and arc-flash duration calculations.

Frequently asked questions

Where can I buy ENW15512 and get a price?

The ENW15512 is sourced to order through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time.

What is ENW15512's control voltage rating?

The closing coil is rated 220/250 V AC/DC at 50/60 Hz, dual-rated for AC control transformers or DC battery-backed buses.

What is the inrush and holding power of this coil?

Inrush is 200 VA or 200 W for 200 ms; holding power drops to 4.5 VA or 4.5 W once the armature seats.

MPN
ENW15512