Skip to main content
Schneider Electric ENW15512

Schneider Electric ENW15512 EasyPact NW Closing Coil, 220/25

MPN ENW15512
Active

Schneider Electric EasyPact NW, XF closing coil, electrically operated, 220/250 V AC/DC 50/60 Hz, 200 VA/W inrush, 4.5 VA/W holding.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW15512 specifications
ParameterValue
Control typeElectrically operated
Control signal typeMaintained
Main product or component typeClosing coil
Coil voltage220...250 V AC/DC 50/60 Hz
ApplicationControl

Product details

Closing coil for EasyPact NW — what the ratings mean

The ENW15512 is a closing coil in the Schneider Electric EasyPact NW range, device short name XF. It's the electrically operated coil that pulls in the main contacts when you apply control voltage — no manual lever, no motor operator, just a maintained signal to close and hold. Rated 220/250 V AC/DC at 50/60 Hz, so it works on either supply without a separate rectifier or DC-DC converter. That dual-rated control voltage simplifies panel wiring — one coil part number covers both the AC control transformer and the DC battery-backed bus common in switchgear. Inrush power hits 200 VA (or 200 W) for 200 ms to overcome the magnetic gap and spring load. Once the armature seats, holding power drops to 4.5 VA or 4.5 W — about 20 mA at 220 V DC. That low sustained draw keeps the control transformer and DC supply lightly loaded in the closed state. The coil is designed for maintained control signal type — voltage stays on to keep the breaker closed. Threshold tripping voltage is 0.85 to 1.1 Un for reliable closing across the full operating range of the control bus.

Integration into the EasyPact NW frame

This coil mounts into the EasyPact NW breaker's control mechanism — the XF designation indicates the closing coil variant for electrically operated breakers. It replaces or upgrades the existing closing coil in the NW frame without modifying the breaker's main pole assembly or arc chamber. Response time is 70 ms across the entire EasyPact MVS current range (100 A through 4000 A), which means the coil's mechanical stroke and magnetic circuit are consistent regardless of the breaker frame size. That 70 ms closing time factors into coordination studies and arc-flash duration calculations.

MPN
ENW15512