Schneider Electric ENW21412 — Air Circuit Breakers

Schneider Electric ENW21412 EasyPact NW Trip Unit, 800-4000

MPNENW21412
Active

Schneider Electric EasyPact NW, Trip System 2.0A control unit, drawout, 800-4000 A, 690 V AC, LI protection, digital display.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

ENW21412 — Identification
ParameterValue
Product typeControl unit
Product rangeEasyPact NW
ENW21412 — Electrical ratings
ParameterValue
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles4P 3P
Network typeAC
Network frequency50/60 Hz
ENW21412 — Mechanical & connection
ParameterValue
Mounting modeDrawout
Width55 mm
Height200 mm
Depth75 mm
Neutral pole positionLeft
ENW21412 — Environmental
ParameterValue
Operating ambient temperature-5...70 °C
Storage ambient temperature-25...85 °C

Product details

Control unit for EasyPact NW drawout breakers

The Schneider Electric ENW21412 is a Trip System 2.0A microprocessor-based control unit for the EasyPact NW range of drawout circuit breakers. It provides LI protection — long-time overload and instantaneous short-circuit — with a trip unit rating adjustable from 800 to 4000 A, rated for 690 V AC at 50/60 Hz per IEC 60947-2.

Protection and coordination features

Long-time pickup (Ir) is adjustable across 9 settings from 0.4 to 1.0 x In, with a corresponding long-time delay adjustable from 0.5 to 24 seconds at 6 x Ir (accuracy 0 to -20%). Instantaneous pickup (Ii) is also adjustable across 9 settings, covering 1.5 to 10 x Ir with +/- 10% accuracy. Zone selective interlocking (ZSI) is built in, enabling coordinated tripping in a selective system — downstream faults clear instantly while upstream breakers wait for their delay, keeping the healthy part of the plant online.

Measurement, display, and diagnostics

The unit measures instantaneous current on all three phases and neutral (I1, I2, I3, In) across a 0.2 to 1.2 In range with +/- 1.5% accuracy, and logs maximum current. A digital display shows fault indications for overload, short-circuit, earth fault, and internal fault.

Pole configuration and neutral protection

The ENW21412 supports 3-pole and 4-pole breaker configurations with the neutral on the left. Protected poles can be set to 3D (three poles, no neutral protection), 3D + N/2 (neutral protected at half the phase pickup), or 4D (all four poles protected). This flexibility lets the same control unit serve solidly-grounded, impedance-grounded, or corner-grounded delta systems without a hardware change.

Frequently asked questions

Where can I buy ENW21412 and how do I get a price?

The ENW21412 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What are the key ratings of the ENW21412 trip unit?

The ENW21412 Trip System 2.0A has a trip unit rating of 800-4000 A, rated operational voltage of 690 V AC, and provides LI protection (long-time and instantaneous) with zone selective interlocking.

What is the ENW21412's depth?

The ENW21412 has a depth of 75 mm.

What is the ENW21412's width?

The ENW21412 has a width of 55 mm.