Schneider Electric ENW21418 — Air Circuit Breakers

ENW21418 EasyPact NW Trip System 6.0A, 800-4000 A

MPNENW21418
Active

Schneider Electric EasyPact NW, Trip System 6.0A control unit, 800-4000 A, LSIG protection, 690 V AC, drawout mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

ENW21418 — Identification
ParameterValue
Product typeControl unit
Product rangeEasyPact NW
ENW21418 — Electrical ratings
ParameterValue
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P 4P
Network typeAC
Network frequency50/60 Hz
ENW21418 — Mechanical & connection
ParameterValue
Mounting modeDrawout
Width55 mm
Height200 mm
Depth75 mm
Neutral pole positionLeft
ENW21418 — Environmental
ParameterValue
Operating ambient temperature-5...70 °C
Storage ambient temperature-25...85 °C

Product details

The ENW21418 is a microprocessor-based control unit for the Schneider Electric EasyPact NW range of air circuit breakers, carrying the Trip System 6.0A designation. It is the brains of the breaker — the part that measures current, decides when to trip, and communicates what happened. Rated for 800 to 4000 A at 690 V AC (50/60 Hz, per IEC 60947-2), it handles the full industrial power distribution band from a large feeder to a main incomer. Protection profile is LSIG: long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I), and ground fault (G). That covers the four protection curves a plant engineer needs for selective coordination — you can set the long-time pickup from 0.4 to 1 x In across nine steps, short-time pickup from 1.5 to 10 x Ir, instantaneous from 2 to 15 x In, and ground-fault pickup from 0.2 to 1 x In (for 400 A < In ≤ 1000 A) or 500 to 1200 x In (for In ≥ 1250 A). Each has its own adjustable time delay, so you can dial in the trip coordination study without swapping hardware. The unit also includes zone selective interlocking (ZSI), which lets multiple breakers in a distribution chain talk to each other over a control wire. When a fault occurs downstream, the breaker closest to the fault trips instantly; upstream breakers hold off for their set delay. That keeps a feeder fault from blacking out the whole switchboard.

Integration notes — drawout, dimensions, and panel fit

The control unit mounts in a drawout cradle — it slides out of the breaker housing without disturbing the power connections. That is the standard arrangement for EasyPact NW frames: the breaker chassis stays wired, and the trip unit comes out for testing, replacement, or setting changes. Dimensions are 75 mm deep, 55 mm wide, 200 mm tall — compact enough that the unit does not steal extra space inside the switchgear cubicle. The digital display shows fault type (overload, short-circuit, earth fault, internal fault) and energy metering data, so a field tech can read the last trip cause without connecting a laptop.

Frequently asked questions

What protection functions does the ENW21418 Trip System 6.0A provide?

The ENW21418 provides LSIG protection: long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I), and ground fault (G). Each function has adjustable pickup and time-delay settings.

What is the rated voltage and current range for ENW21418?

The ENW21418 is rated for 690 V AC at 50/60 Hz per IEC 60947-2, with a trip unit rating of 800 to 4000 A.

What compliance documentation does Schneider Electric provide for ENW21418?

The ENW21418 is designed and tested to IEC 60947-2. Schneider Electric provides the standard compliance documentation for the EasyPact NW range. Contact us with your RFQ for specific documentation requests.

MPN
ENW21418