Schneider Electric ENW21422 — Air Circuit Breakers

Schneider Electric ENW21422 Trip Unit, EasyPact NW, 800-4000

MPNENW21422
Active

Schneider Electric EasyPact NW, Trip System 2.0A, control unit, LI protection, 800-4000 A, 690 V AC, fixed mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

ENW21422 — Identification
ParameterValue
Product typeControl unit
Product rangeEasyPact NW
ENW21422 — Electrical ratings
ParameterValue
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P 4P
Network typeAC
Network frequency50/60 Hz
ENW21422 — Mechanical & connection
ParameterValue
Mounting modeFixed
Width55 mm
Height200 mm
Depth75 mm
Neutral pole positionLeft
ENW21422 — Environmental
ParameterValue
Operating ambient temperature-5...70 °C
Storage ambient temperature-25...85 °C

Product details

What this trip unit does on the line

The ENW21422 is the brains for an EasyPact NW air circuit breaker — the Trip System 2.0A control unit that decides when to hold and when to trip. It covers the 800 to 4000 A range at 690 V AC, with LI protection: overload (long-time) and instantaneous short-circuit. That means you get adjustable long-time pickup from 0.4 to 1 x In and instantaneous pickup from 1.5 to 10 x Ir, both with nine settings each. The long-time delay stretches from 0.5 to 24 seconds at 6 x Ir, so you can shape the curve for coordination downstream.

Field diagnostics that save a midnight call

This unit has a digital display and fault indication for short-circuit, internal fault, overload, and earth fault. It measures instantaneous current on all three phases plus neutral, 0.2 to 1.2 In with ±1.5% accuracy, and logs maximum current the same way. That means when a line drops, you walk up and read the last fault — no laptop needed.

Selectivity and coordination

Zone selective interlocking (ZSI) is built in. That lets multiple breakers in a cascade communicate during a fault — the downstream breaker clears the fault instantly without waiting for the upstream unit to time out, while a fault between breakers still gets full coordination. For standard industrial applications, this is what keeps a single feeder fault from taking out the whole switchboard. Neutral protection is configurable: 3D (no neutral protection), 3D + N/2 (half-rated neutral), or 4D (full neutral protection). Poles description covers 3P and 4P configurations.

Frequently asked questions

What is ENW21422's trip unit rating?

The Trip System 2.0A control unit covers 800 to 4000 A, adjustable via long-time pickup from 0.4 to 1 x In and instantaneous pickup from 1.5 to 10 x Ir.

Where can I buy ENW21422?

The ENW21422 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.

What protection functions does ENW21422 provide?

LI protection: overload (long-time) and instantaneous short-circuit. Long-time delay is adjustable 0.5 to 24 s at 6 x Ir; instantaneous pickup is adjustable 1.5 to 10 x Ir.

MPN
ENW21422