Schneider Electric ENW21422

Schneider Electric ENW21422 Trip Unit, EasyPact NW, 800-4000

MPN ENW21422
Active

Schneider Electric EasyPact NW, Trip System 2.0A, control unit, LI protection, 800-4000 A, 690 V AC, fixed mounting.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW21422 specifications
ParameterValue
Display typeDigital display
Trip unit typeMicro-processor based
Main product or component typeControl unit
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Temp storage max85 °C
Temp storage min-25 °C
Temp operating max70 °C
Temp operating min-5 °C
Storage temperature-25...85 °C
Depth75 mm
Width55 mm
Height200 mm
Operating temperature-5...70 °C

Product details

What this trip unit does on the line

The ENW21422 is the brains for an EasyPact NW air circuit breaker — the Trip System 2.0A control unit that decides when to hold and when to trip. It covers the 800 to 4000 A range at 690 V AC, with LI protection: overload (long-time) and instantaneous short-circuit. That means you get adjustable long-time pickup from 0.4 to 1 x In and instantaneous pickup from 1.5 to 10 x Ir, both with nine settings each. The long-time delay stretches from 0.5 to 24 seconds at 6 x Ir, so you can shape the curve for coordination downstream.

Field diagnostics that save a midnight call

This unit has a digital display and fault indication for short-circuit, internal fault, overload, and earth fault. It measures instantaneous current on all three phases plus neutral, 0.2 to 1.2 In with ±1.5% accuracy, and logs maximum current the same way. That means when a line drops, you walk up and read the last fault — no laptop needed.

Selectivity and coordination

Zone selective interlocking (ZSI) is built in. That lets multiple breakers in a cascade communicate during a fault — the downstream breaker clears the fault instantly without waiting for the upstream unit to time out, while a fault between breakers still gets full coordination. For standard industrial applications, this is what keeps a single feeder fault from taking out the whole switchboard. Neutral protection is configurable: 3D (no neutral protection), 3D + N/2 (half-rated neutral), or 4D (full neutral protection). Poles description covers 3P and 4P configurations.