Skip to main content
Schneider Electric ENW21425 — Air Circuit Breakers

Schneider Electric ENW21425 EasyPact NW Trip System 5.0A, 80

MPNENW21425
Active

Schneider Electric EasyPact NW, Trip System 5.0A control unit, ENW21425, LSI protection, 800…4000 A, 690 V AC, digital display, fixed mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

ENW21425 — Identification
ParameterValue
Product typeControl unit
Product rangeEasyPact NW
ENW21425 — Electrical ratings
ParameterValue
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P 4P
Network typeAC
Network frequency50/60 Hz
ENW21425 — Mechanical & connection
ParameterValue
Mounting modeFixed
Width55 mm
Height200 mm
Depth75 mm
Neutral pole positionLeft
ENW21425 — Environmental
ParameterValue
Operating ambient temperature-5...70 °C
Storage ambient temperature-25...85 °C

Product details

Trip System 5.0A — LSI protection for EasyPact NW

The Schneider Electric ENW21425 is a microprocessor-based control unit for the EasyPact NW range of air circuit breakers. It carries the Trip System 5.0A designation and provides LSI protection: long-time overload, short-time short-circuit, and instantaneous short-circuit, plus earth-fault indication. The rating spans 800…4000 A at 690 V AC 50/60 Hz, compliant with IEC 60947-2. The unit offers adjustable long-time pickup from 0.4 to 1 x In across nine settings, long-time delay from 0.5 to 24 s at 6 x Ir, short-time pickup from 1.5 to 10 x Ir with delay from 100 to 400 ms, and instantaneous pickup from 2 to 15 x In. Zone selective interlocking (ZSI) is included, which coordinates downstream breakers to clear a fault at the nearest device without waiting for the upstream delay. A digital display shows instantaneous and maximum current per phase (I1, I2, I3, In) with ±1.5 % accuracy, and the unit logs fault type — short-circuit, overload, internal fault, earth fault.

Mounting and integration in the panel

The unit is rated for standard industrial applications and is part of the EasyPact NW family — a common choice for main and feeder breakers in LV switchgear.

Frequently asked questions

What is ENW21425's listed depth (75 mm) on this component line?

The ENW21425 control unit has a depth of 75 mm, a width of 55 mm, and a height of 200 mm.

What is ENW21425's listed width (55 mm) on this component line?

The ENW21425 control unit has a width of 55 mm, a depth of 75 mm, and a height of 200 mm.

MPN