Schneider Electric ENW21426 — Air Circuit Breakers

Schneider Electric ENW21426 EasyPact NW Trip Unit, Trip Syst

MPNENW21426
Active

Schneider Electric EasyPact NW, Trip System 5.0E, control unit, LSI protection, 800–4000 A, 690 V AC, fixed mounting, digital display.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

ENW21426 — Identification
ParameterValue
Product typeControl unit
Product rangeEasyPact NW
ENW21426 — Electrical ratings
ParameterValue
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles4P 3P
Network typeAC
Network frequency50/60 Hz
ENW21426 — Mechanical & connection
ParameterValue
Mounting modeFixed
Width55 mm
Height200 mm
Depth75 mm
Neutral pole positionLeft
ENW21426 — Environmental
ParameterValue
Operating ambient temperature-5...70 °C
Storage ambient temperature-25...85 °C

Product details

Control unit for EasyPact NW — Trip System 5.0E

The Schneider Electric ENW21426 is a microprocessor-based control unit for the EasyPact NW range of air circuit breakers. It carries the Trip System 5.0E designation and provides LSI protection — long-time, short-time, and instantaneous — with a trip unit rating adjustable from 800 A to 4000 A. The unit supports 4P and 3P pole configurations with neutral position on the left, and offers selectable neutral protection settings: 3D (no protection), 3D + N/2 (0.5 × Ir), or 4D (1 × Ir).

Protection and coordination

Long-time pick-up (Ir) is adjustable across 0.4–1 × In with nine settings, and the long-time delay (Tr) ranges from 0.5 to 24 seconds at 6 × Ir, accuracy 0 to −20%. Short-time pick-up (Isd) adjusts from 1.5 to 10 × Ir with nine settings, and the short-time delay (Tsd) is selectable from 100 to 400 ms. Instantaneous pick-up (Ii) covers 2–15 × In, also with nine settings, and can be switched off. Zone selective interlocking (ZSI) is built in, allowing the trip unit to communicate with upstream and downstream breakers for faster fault clearing while maintaining selectivity.

Monitoring and indication

The unit includes a digital display and an energy meter for local measurement. Fault indication covers internal fault, overload, short-circuit, and earth fault conditions.

Frequently asked questions

What protection functions does the ENW21426 Trip System 5.0E provide?

It provides LSI protection: long-time overload, short-time short-circuit, and instantaneous short-circuit protection, all independently adjustable.

What is the rated voltage and standard for ENW21426?

Rated operational voltage is 690 V AC at 50/60 Hz, conforming to IEC 60947-2.

Where can I buy ENW21426?

The ENW21426 is available to order through independent distribution; submit an RFQ for current availability and pricing.