Schneider Electric ENW21432 — Air Circuit Breakers

ENW21432 EasyPact NW Trip Unit, 800-4000 A, LI Protection

MPNENW21432
Active

Schneider Electric EasyPact NW, Trip System 2.0A control unit, 800-4000 A, LI protection, digital display, 690 V AC, 50/60 Hz, fixed mount, 75 x 55 x 200 mm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

ENW21432 — Identification
ParameterValue
Product typeControl unit
Product rangeEasyPact NW
ENW21432 — Electrical ratings
ParameterValue
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P 4P
Network typeAC
Network frequency50/60 Hz
ENW21432 — Mechanical & connection
ParameterValue
Mounting modeFixed
Width55 mm
Height200 mm
Depth75 mm
Neutral pole positionLeft
ENW21432 — Environmental
ParameterValue
Operating ambient temperature-5...70 °C
Storage ambient temperature-25...85 °C

Product details

What this trip unit does

The ENW21432 is a microprocessor-based control unit for the EasyPact NW range of drawout air circuit breakers. It provides LI protection — long-time overload and instantaneous short-circuit — with a trip unit rating adjustable from 800 A to 4000 A. The digital display shows energy metering and fault indication for overload, short-circuit, earth fault, and internal faults.

Protection and adjustment

Long-time pickup (Ir) is adjustable from 0.4 to 1.0 x In across 9 settings. The long-time delay (Tr) ranges from 0.5 to 24 seconds at 6 x Ir, with an accuracy of 0 to -20%. Instantaneous pickup (Ii) adjusts from 1.5 to 10 x Ir, also with 9 settings and ±10% accuracy. Zone selective interlocking (ZSI) is included for faster fault clearing in coordinated systems.

Mounting and configuration

This control unit mounts fixed to the EasyPact NW breaker frame. Physical dimensions are 75 mm deep, 55 mm wide, and 200 mm tall. Neutral protection is configurable: no protection (3D), 0.5 x Ir (3D+N/2), or 1 x Ir (4D). Protected poles can be set to 3D, 4D, or 3D+N/2. Neutral position is left.

The ENW21432 is an active, current-production part.

Frequently asked questions

What is the trip rating range of ENW21432?

The trip unit rating is adjustable from 800 A to 4000 A.

What protection functions does ENW21432 provide?

It provides LI protection: long-time overload and instantaneous short-circuit, with configurable pickup and delay settings.

What are the physical dimensions of ENW21432?

Depth is 75 mm, width is 55 mm, and height is 200 mm.

Where can I buy ENW21432 and how is it quoted?

The ENW21432 is sourced to order through independent distribution. Submit an RFQ for current pricing and availability; lead time and stock are confirmed at quote time.