Schneider Electric EasyPact NW, Trip System 5.0E, microprocessor-based control unit, 800-4000 A, LSI protection, 690 V AC, 4P/3P.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

ENW21436 — Identification
ParameterValue
Product typeControl unit
Product rangeEasyPact NW
ENW21436 — Electrical ratings
ParameterValue
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles4P 3P
Network typeAC
Network frequency50/60 Hz
ENW21436 — Mechanical & connection
ParameterValue
Mounting modeFixed
Width55 mm
Height200 mm
Depth75 mm
Neutral pole positionLeft
ENW21436 — Environmental
ParameterValue
Operating ambient temperature-5...70 °C
Storage ambient temperature-25...85 °C

Product details

Trip unit for EasyPact NW — Trip System 5.0E, 800–4000 A

The Schneider Electric ENW21436 is a microprocessor-based control unit for the EasyPact NW range of drawout circuit breakers. It carries the Trip System 5.0E designation and is rated for an 800 to 4000 A trip unit setting, with a rated operational voltage of 690 V AC at 50/60 Hz per IEC 60947-2. Protection functions are LSI: overload (long-time), short-time short-circuit, and instantaneous short-circuit. The long-time pickup adjusts from 0.4 to 1 x In across nine settings, with a delay range of 0.5 to 24 seconds at 6 x Ir. Short-time pickup adjusts from 1.5 to 10 x Ir over nine settings, with delays from 100 to 400 ms. Instantaneous pickup adjusts from 2 to 15 x In, also over nine settings, with an Off position available. Zone selective interlocking (ZSI) is included, allowing coordination between downstream and upstream breakers to clear faults faster while maintaining selectivity. Fault indication covers internal fault, overload, short-circuit, and earth fault.

Integration and configuration

The unit mounts fixed in the EasyPact NW drawout cradle. Neutral protection is configurable: 3D (no protection), 3D + N/2 (0.5 x Ir), or 4D (1 x Ir). The neutral conductor is on the left side. Poles are 4P or 3P, with protected poles selectable as 4D, 3D + N/2, or 3D.

Frequently asked questions

What protection functions does the ENW21436 Trip System 5.0E provide?

It provides LSI protection: long-time overload, short-time short-circuit, and instantaneous short-circuit protection.

What is the trip unit rating range for ENW21436?

The trip unit rating range is 800 to 4000 A.

Where can I buy ENW21436 and how is it quoted?

The ENW21436 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.