Skip to main content
Schneider Electric ENW21439 — Air Circuit Breakers

Schneider Electric ENW21439 EasyPact NW Control Unit, LSIG,

MPNENW21439
Active

Schneider Electric EasyPact NW, control unit, Trip System 6.0E, LSIG protection, 800-4000 A trip rating, 690 V AC, microprocessor-based, digital display, 75 x 55 x 200 mm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

ENW21439 — Identification
ParameterValue
Product typeControl unit
Product rangeEasyPact NW
ENW21439 — Electrical ratings
ParameterValue
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles4P 3P
Network typeAC
Network frequency50/60 Hz
ENW21439 — Mechanical & connection
ParameterValue
Mounting modeFixed
Width55 mm
Height200 mm
Depth75 mm
Neutral pole positionLeft
ENW21439 — Environmental
ParameterValue
Operating ambient temperature-5...70 °C
Storage ambient temperature-25...85 °C

Product details

What this control unit does

The Schneider Electric ENW21439 is a microprocessor-based control unit for the EasyPact NW range of air circuit breakers. It provides LSIG protection — long-time, short-time, instantaneous, and ground-fault — configurable through the Trip System 6.0E. The trip unit rating spans 800 to 4000 A, making it suitable for large industrial feeders and main incomers on 690 V AC networks at 50/60 Hz, conforming to IEC 60947-2.

Protection curves and adjustability

Each protection function is independently adjustable. Long-time pickup (Ir) has 9 settings from 0.4 to 1 x In, with a corresponding time delay (Tr) adjustable in 9 steps from 0.5 to 24 s at 6 x Ir. Short-time pickup (Isd) adjusts in 9 steps from 1.5 to 10 x Ir, with delay (Tsd) in 5 steps from 100 to 400 ms. Instantaneous pickup (Ii) has 9 settings from 2 to 15 x In, and can be switched off. Ground-fault pickup (Ig) adjusts in 9 steps: 0.2 to 1 x In for ratings up to 1000 A, and 500 to 1200 x In for 1250 A and above. Zone selective interlocking (ZSI) is included for coordinated tripping in a distribution hierarchy.

Thermal memory and fault indication

Fault indication covers overload, short-circuit, earth fault, and internal fault, shown on the digital display. The neutral protection setting is configurable: no protection (3D), 0.5 x Ir (3D + N/2), or 1 x Ir (4D). Protected poles can be set to 4D, 3D + N/2, or 3D.

Frequently asked questions

Where can I buy ENW21439?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What protection functions does ENW21439 provide?

It provides LSIG protection: long-time, short-time, instantaneous, and ground-fault, all independently adjustable.

What is the trip unit rating range for ENW21439?

The trip unit rating is adjustable from 800 to 4000 A.

What is the rated operational voltage for ENW21439?

The rated operational voltage is 690 V AC 50/60 Hz, conforming to IEC 60947-2.

MPN
ENW21439