Schneider Electric ENW21439 EasyPact NW Control Unit, LSIG,

MPN ENW21439
Active

Schneider Electric EasyPact NW, control unit, Trip System 6.0E, LSIG protection, 800-4000 A trip rating, 690 V AC, microprocessor-based, digital display, 75 x 55 x 200 mm.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW21439 specifications
ParameterValue
Display typeDigital display
Trip unit typeMicro-processor based
Main product or component typeControl unit
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Temp storage max85 °C
Temp storage min-25 °C
Temp operating max70 °C
Temp operating min-5 °C
Storage temperature-25...85 °C
Depth75 mm
Width55 mm
Height200 mm
Operating temperature-5...70 °C

Product details

What this control unit does

The Schneider Electric ENW21439 is a microprocessor-based control unit for the EasyPact NW range of air circuit breakers. It provides LSIG protection — long-time, short-time, instantaneous, and ground-fault — configurable through the Trip System 6.0E. The trip unit rating spans 800 to 4000 A, making it suitable for large industrial feeders and main incomers on 690 V AC networks at 50/60 Hz, conforming to IEC 60947-2.

Protection curves and adjustability

Each protection function is independently adjustable. Long-time pickup (Ir) has 9 settings from 0.4 to 1 x In, with a corresponding time delay (Tr) adjustable in 9 steps from 0.5 to 24 s at 6 x Ir. Short-time pickup (Isd) adjusts in 9 steps from 1.5 to 10 x Ir, with delay (Tsd) in 5 steps from 100 to 400 ms. Instantaneous pickup (Ii) has 9 settings from 2 to 15 x In, and can be switched off. Ground-fault pickup (Ig) adjusts in 9 steps: 0.2 to 1 x In for ratings up to 1000 A, and 500 to 1200 x In for 1250 A and above. Zone selective interlocking (ZSI) is included for coordinated tripping in a distribution hierarchy.

Thermal memory and fault indication

Fault indication covers overload, short-circuit, earth fault, and internal fault, shown on the digital display. The neutral protection setting is configurable: no protection (3D), 0.5 x Ir (3D + N/2), or 1 x Ir (4D). Protected poles can be set to 4D, 3D + N/2, or 3D.