ENW21526 EasyPact NW Closing Coil, 48/60 VDC, Active

MPNENW21526
Active

Schneider Electric EasyPact NW, XF closing coil, 48/60 VDC, electrically operated, maintained control, 4.5 W/VA holding power, fixed mounting.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

ENW21526 — Identification
ParameterValue
Product typeClosing coil
RangeEasyPact
Product rangeEasyPact NW
ApplicationControl
ENW21526 — Mechanical & connection
ParameterValue
Control typeElectrically operated
Mounting modeFixed
ENW21526 — Other specifications
ParameterValue
Device short nameXF
Control signal typeMaintained
Supply holding power4.5 W 4.5 VA
Voltage release typeClosing coil
Coil voltage48/60 V DC

Product details

Closing coil for EasyPact NW — 48/60 VDC, electrically operated

The ENW21526 is a closing coil for the Schneider Electric EasyPact NW range — a fixed-mount, electrically operated coil (XF device short name) that draws and holds the main contacts closed on maintained control signals. Control circuit voltage is 48/60 V DC, with a holding power draw of 4.5 W / 4.5 VA.

The 48/60 V DC control voltage is a dual-range coil — it operates on either nominal, so a 48 VDC control supply or a 60 VDC battery-backed bus both work without a separate dropping resistor. The 4.5 W / 4.5 VA holding power is low enough that a standard 24 VDC pilot-device transformer with a rectifier can supply it, but confirm the inrush at pickup if the coil is cycled frequently — the holding figure is steady-state, not peak pull-in. The electrically operated, maintained control type means the coil stays energized to keep the breaker closed; a loss of control power drops the breaker open (trip-free mechanism).

Integration into the EasyPact NW breaker

This is a fixed-mount accessory for the EasyPact NW air circuit breaker family. It installs into the breaker's mechanism housing; no DIN-rail or panel cutout required — it's internal to the breaker chassis. The XF designation indicates the closing-coil variant, distinct from the MX shunt trip or MCH motor-mechanism coils in the same range. Verify breaker frame compatibility: the EasyPact NW covers NW08 through NW63 frames; the coil's mechanical interface is common across the range, but the control-wire routing differs between draw-out and fixed versions.

Frequently asked questions

What is the control voltage for ENW21526?

The control circuit voltage is 48/60 V DC — a dual-range coil that operates on either 48 VDC or 60 VDC without modification.