Schneider Electric ENW22324 — Air Circuit Breakers

Schneider Electric ENW22324 EasyPact NW Chassis, 4000A, 4P,

MPNENW22324
Active

Schneider Electric EasyPact NW chassis, ENW22324, 4000 A at 40 °C, 4 poles, H breaking capacity, drawout mounting.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ENW22324 — Identification
ParameterValue
Product typeChassis
RangeEasyPact
Product rangeEasyPact NW
ApplicationMounting

Electrical ratings

ENW22324 — Electrical ratings
ParameterValue
Rated current (In)4000 A at 40 °C
Poles4P

Breaking & withstand capacity

ENW22324 — Breaking & withstand capacity
ParameterValue
Breaking capacity codeH

Mechanical & connection

ENW22324 — Mechanical & connection
ParameterValue
Mounting modeDrawout
Width400 mm
Height440 mm
Depth560 mm

Other specifications

ENW22324 — Other specifications
ParameterValue
Device short nameENW40H

Product details

Chassis for high-current drawout applications

The Schneider Electric ENW22324 is a chassis for the EasyPact NW range, rated 4000 A at 40 °C across 4 poles with an H breaking capacity code. This is the frame that carries the switching mechanism and arc chamber — it mounts via drawout, meaning the entire power assembly can be racked out for inspection or replacement without disturbing the fixed buswork. That 4000 A rating places it squarely in large low-voltage switchgear for industrial plants, data center main distribution, or utility substations where continuous current demand is high and downtime for maintenance must be minimized.

Drawout integration and panel fit

Drawout mounting means the chassis slides into a fixed cradle with self-aligning primary disconnects — no bolted bus connections to break during racking. The physical envelope is 560 mm deep, 400 mm wide, 440 mm high. That depth is the critical dimension for enclosure selection: the cubicle must accommodate the full travel of the racking mechanism plus clearance for the arc chute exhaust. Standard 600 mm deep switchgear lineups typically fit this chassis, but verify the cradle height and bus riser spacing against the 440 mm height.

Frequently asked questions

What is ENW22324's rated current and breaking capacity?

The ENW22324 is rated 4000 A at 40 °C with an H breaking capacity code. The H code indicates a higher short-circuit withstand capability within the EasyPact NW family, suitable for installations with high prospective fault current.

How do I get current pricing and availability for ENW22324?

Current pricing and availability are confirmed at quote time. Submit an RFQ through the storefront — the part is sourced to order through independent distribution channels, and a quote will reflect real-time market conditions.

What is ENW22324's listed depth?

The ENW22324 has a depth of 560 mm. This is the dimension from the front of the chassis to the rear of the arc chute, critical for enclosure depth selection in drawout switchgear.

MPN
ENW22324