Schneider Electric ENW24106

Schneider Electric ENW24106 EasyPact NW Circuit Breaker, 250

MPN ENW24106
Active

Schneider Electric EasyPact NW, circuit breaker, ENW24106, 3P, 2500 A at 40 °C, 50 kA Icu at 440 V AC, drawout mounting.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW24106 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C

All specifications

ENW24106 additional specifications
ParameterValue
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width441 mm
Height439 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...60 °C

Product details

The ENW24106 is a 3-pole EasyPact NW circuit breaker rated 2500 A at 40 °C, with a breaking capacity of 50 kA Icu at 220…440 V AC 50/60 Hz conforming to IEC 60947-2. At 690 V the Icu drops to 42 kA, still sufficient for most industrial secondary distribution. The drawout mounting means the breaker chassis slides into a fixed cradle, allowing safe isolation and replacement without unbolting busbars — standard for switchgear lineups where maintenance access matters. Rated insulation voltage (Ui) is 1000 V AC, and the impulse withstand (Uimp) is 12 kV, confirming the part is designed for systems where transient overvoltages are a concern — typical in industrial environments with motor starts and capacitor switching.

Deployment context

This breaker is a drawout unit designed for mounting on a rail in low-voltage switchgear assemblies. The rear connection position with a 115 mm pitch without spreader matches standard busbar take-off spacing in common switchgear cubicles.

Key approvals and standards

Certified to IEC 60947-2 for low-voltage switchgear and controlgear. Suitability for isolation means it can be used as a disconnecting means per code. Electrical durability is 5000 cycles at 440 V and 2500 cycles at 690 V without maintenance; mechanical durability is 20000 cycles with maintenance, 10000 without. These figures guide preventive maintenance scheduling — plan inspection at the 5000-cycle mark for typical 440 V distribution.

MPN