Schneider Electric ENW24108 — Air Circuit Breakers

Schneider Electric ENW24108 EasyPact NW Circuit Breaker, 400

MPNENW24108
Active

Schneider Electric EasyPact NW, air circuit breaker, ENW24108, 4000 A rated current, 55 kA Icu at 440 V AC, 3P, drawout mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ENW24108 — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact NW
ApplicationDistribution

Electrical ratings

ENW24108 — Electrical ratings
ParameterValue
Rated current (In)4000 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2

Breaking & withstand capacity

ENW24108 — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)55 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 55 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)88 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2 121 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity55 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeN

Performance

ENW24108 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 5000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 2500 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B

Mechanical & connection

ENW24108 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportRail
Contact position indicatorYes
Width441 mm
Height439 mm
Depth395 mm
Connection pitch115 mm without spreader
Connection locationRear

Environmental

ENW24108 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1

Approvals

ENW24108 — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

Rating and application context

The Schneider Electric ENW24108 is a 3-pole air circuit breaker from the EasyPact NW range, rated 4000 A at 40 °C with a breaking capacity of 55 kA Icu at 220...440 V AC and 42 kA Icu at 690 V AC, per IEC 60947-2. The drawout mounting allows the breaker to be racked out for maintenance or replacement without disturbing the bus connections, a standard requirement for switchgear lineups where uptime matters.

Withstand and coordination

The short-time withstand current (Icw) is 55 kA for 1 s at 220...440 V and 42 kA for 1 s at 690 V, with a 3 s rating of 30 kA at 440/690 V. This Icw value is the one you size selective coordination against — if the downstream breaker clears a fault within 1 s, this breaker must hold closed without damage.

Integration notes

Drawout mounting with rear connections — the breaker slides into a fixed cradle with horizontal or vertical connection orientation. The 115 mm connection pitch without spreader matches standard switchgear bus spacing.

Rated insulation voltage 1000 V AC, operational voltage 690 V AC. Electrical durability is 5000 cycles at 440 V and 2500 cycles at 690 V without maintenance; mechanical durability 20000 cycles with maintenance, 10000 without.

Frequently asked questions

What are the key ratings for ENW24108?

Rated current 4000 A at 40 °C, breaking capacity 55 kA Icu at 220...440 V AC and 42 kA at 690 V AC, rated operational voltage 690 V AC, rated insulation voltage 1000 V AC.

Where can I buy ENW24108?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

What standards does ENW24108 comply with?

Compliant with IEC 60947-2 and suitable for isolation per that standard. Pollution degree 4 per IEC 60664-1.