Schneider Electric ENW24109 — Air Circuit Breakers

Schneider Electric ENW24109 EasyPact NW Circuit Breaker, 800

MPNENW24109
Active

Schneider Electric EasyPact NW series, ENW24109 air circuit breaker, 3-pole, 800 A rated current, 50 kA Icu at 440 V AC, IEC 60947-2 compliant.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ENW24109 — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact NW
ApplicationDistribution

Electrical ratings

ENW24109 — Electrical ratings
ParameterValue
Rated current (In)800 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2

Breaking & withstand capacity

ENW24109 — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)50 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)50 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 25 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)105 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 88 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeN

Performance

ENW24109 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 4000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B

Mechanical & connection

ENW24109 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeFixed
Mounting supportBase plate
Contact position indicatorYes
Width422 mm
Height352 mm
Depth297 mm
Connection pitch115 mm without spreader
Connection locationRear

Environmental

ENW24109 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1

Approvals

ENW24109 — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

What this breaker delivers

The Schneider Electric ENW24109 is an EasyPact NW air circuit breaker rated for 800 A at 40 °C, with a 50 kA Icu breaking capacity at 220…440 V AC. At 690 V AC the Icu drops to 42 kA, still a solid number for a 690 V bus. The Ics (service breaking capacity) matches the Icu at both voltage levels, meaning the breaker can be reclosed immediately after clearing a fault without derating — a practical advantage for continuous-process lines where a downstream fault shouldn't force a breaker replacement. Rated insulation voltage (Ui) is 1000 V AC, and the impulse withstand (Uimp) is 12 kV, so it's comfortable on 690 V systems with reasonable surge exposure.

This is a fixed-mount, rear-connected breaker on a base plate — no draw-out cradle, no DIN-rail clip. Panel cut-out and bus-bar layout need to accommodate the 422 mm width, 352 mm height, and 297 mm depth. The rear connection pitch is 115 mm without a spreader, so bus-bar drilling matches that spacing. IP40 protection means it's fine inside a clean enclosure but not for washdown areas or outdoor cabinets without additional weatherproofing. Pollution degree 4 per IEC 60664-1 is the highest standard rating — it tolerates conductive dust and condensation, common in industrial environments like cement plants, foundries, or grain handling. The control is push-button operated with a contact position indicator, so the operator can see open/closed status at a glance without auxiliary lamps.

Designed and tested to IEC 60947-2 for low-voltage switchgear and controlgear. Mechanical durability is 20,000 cycles with maintenance, 10,000 without; electrical durability at 440 V is 6,000 cycles without maintenance under Category B duty. That Category B classification means it's intended for distribution applications where the breaker sees infrequent switching — not for motor starting or frequent load cycling.

Frequently asked questions

What is the breaking capacity of ENW24109?

50 kA Icu at 220…440 V AC and 42 kA Icu at 690 V AC, both per IEC 60947-2. The Ics (service breaking capacity) is the same as the Icu at each voltage level.

Where can I buy ENW24109 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What compliance documentation does Schneider provide for ENW24109?

The breaker is designed to IEC 60947-2 and carries a suitability-for-isolation declaration per that standard. Pollution degree 4 per IEC 60664-1 is specified. For RoHS, REACH, and UL documentation, request the manufacturer's compliance declarations with your RFQ.

MPN