Schneider Electric ENW24112 — Air Circuit Breakers

Schneider Electric ENW24112 EasyPact NW Circuit Breaker, 160

MPNENW24112
Active

Schneider Electric EasyPact NW, ENW24112, 3-pole circuit breaker, 1600 A at 40 °C, 50 kA Icu at 440 V AC, IEC 60947-2.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ENW24112 — Identification
ParameterValue
Product typeCircuit breaker
RangeEasyPact
Product rangeEasyPact NW
ApplicationDistribution

Electrical ratings

ENW24112 — Electrical ratings
ParameterValue
Rated current (In)1600 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)12 kV conforming to IEC 60947-2
Network typeAC
Network frequency50/60 Hz
Suitable for isolationYes conforming to IEC 60947-2

Breaking & withstand capacity

ENW24112 — Breaking & withstand capacity
ParameterValue
Rated service breaking capacity (Ics)50 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-time withstand current (Icw)50 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 25 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated short-circuit making capacity (Icm)105 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 88 kA (Icm) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity50 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeN

Performance

ENW24112 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability (cycles)Category B: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 4000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Utilisation categoryCategory B

Mechanical & connection

ENW24112 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeFixed
Mounting supportBase plate
Contact position indicatorYes
Width422 mm
Height352 mm
Depth297 mm
Connection pitch115 mm without spreader
Connection locationRear

Environmental

ENW24112 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C without control unit -25...85 °C with control unit
IP degree of protectionIP40
Pollution degree4 conforming to IEC 60664-1

Approvals

ENW24112 — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

The ENW24112 is a 3-pole air circuit breaker from the Schneider Electric EasyPact NW range, rated 1600 A at 40 °C. At 690 V AC the Icu drops to 42 kA, still substantial for most industrial supplies. The Ics (service breaking capacity) matches the Icu at each voltage level — 50 kA and 42 kA respectively — so after clearing a fault at full rating the breaker remains fit for further service, not just a one-shot device.

Deployment context

Fixed-mount design on a base plate, with rear connections and a vertical or horizontal orientation. The 422 mm width, 352 mm height, and 297 mm depth define the panel cutout and enclosure size — plan for a dedicated compartment in the switchboard, not a DIN-rail clip-in. IP40 protection means it's suitable for indoor panel installation where no water spray is present. The push-button control type provides local manual operation for maintenance switching and isolation.

Frequently asked questions

What is ENW24112's breaking capacity?

The breaking capacity is 50 kA Icu at 220...440 V AC and 42 kA Icu at 690 V AC, both per IEC 60947-2.

MPN